5.4 Settings That Must Be Adjusted to the System
5.4.6 Software Reset
5-30
5.4.6
Software Reset
You can reset the SERVOPACK internally with the software. A software reset is used when
resetting alarms and changing the settings of parameters that normally require turning the
power supply to the SERVOPACK OFF and ON again. This can be used to change those
parameters without turning the power supply to the SERVOPACK OFF and ON again.
Preparations
Confirm that the following conditions are met before you perform a software reset.
•
The system must be in the SERVO OFF state.
•
The motor must be stopped.
Operating Procedure
Use the following procedure to perform a software reset.
1.
Select
Setup - Software Reset
from the menu bar of the Main Window of the Sig-
maWin+.
2.
Click the
Execute
Button.
Click the
Cancel
Button to cancel the software reset. The Main Window will return.
3.
Click the
Execute
Button.
1. Always confirm that the system is in the SERVO OFF state and that the motor is stopped
before you start a software reset.
2. This function resets the SERVOPACK independently of the host controller. The SERVO-
PACK carries out the same processing as when the power supply is turned ON and out-
puts the ALM (Servo Alarm) signal. The status of other output signals may be forcibly
changed.
3. When you execute a software reset, the SERVOPACK will not respond for approximately three
seconds.
Before you execute a software reset, check the status of the SERVOPACK and Servomo-
tor and make sure that no problems will occur.
Information