8 Overview of Keypad Components and Functions
34
YASKAWA
TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
8
Overview of Keypad Components and Functions
Figure 8.1 Keypad
Table 8.1 Keypad Components and Functions
Sym
bol
Name
Function
A
USB Terminal
Pass-through
Pass-through point to connect a USB cable to the drive to use the DriveWizard PC
tool or the DriveWizard Mobile App to program the drive. Uses a USB cable
(USB standard 2.0, type A - mini-B) to connect the drive to a PC, Android
smartphone, or tablet.
B
RUN Key
Starts the drive in LOCAL Mode.
Starts the operation in Auto-Tuning Mode.
Note:
Before you use the keypad to operate the motor, push
on the keypad to
set the drive to LOCAL Mode.
C
STOP Key
Stops drive operation.
Note:
Uses a stop-priority circuit. Push
to stop the motor. This will also
apply when a Run command (REMOTE Mode) is active at an external Run
command source. To disable
priority, set
o2-02 = 0 [STOP Key
Function Selection = Disabled]
.