i.10 European Standards
Figure i.19 CE Mark
The CE mark indicates compliance with European safety and environmental regulations. It is required for engaging in business
and commerce in Europe.
European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for electronics
manufacturers, and the EMC guidelines for controlling noise.
This drive is in conformance with the Low Voltage Directive.
•
Low Voltage Directive:
2006/95/EC
Devices used in combination with this drive must also be CE certified and display the CE mark. When using drives displaying
the CE mark in combination with other devices, it is ultimately the responsibility of the user to ensure compliance with CE
standards. After setting up the device, verify that conditions meet European standards.
u
CE Low Voltage Directive Compliance
This drive has been tested according to European standard IEC/EN 61800-5-1, and it fully complies with the Low Voltage
Directive.
To comply with the Low Voltage Directive, be sure to meet the following conditions when combining this drive with other
devices:
n
Area of Use
Do not use drives in areas with pollution higher than degree 2 and overvoltage category 3 in accordance with IEC/EN 664.
n
Factory Recommended Branch Circuit Protection
NOTICE
Refer to the Z1000 User Manual (600 V models) TOEPYAIZ1U03; Chapter-
Standards Compliance
,
Section-European
Standards
, for more information on
Factory Recommended Branch Circuit Protection
for CE Compliance.
To obtain instruction manuals for Yaskawa products access : http://www.yaskawa.com
n
Grounding
The drive is designed to be used in T-N (grounded neutral point) networks. If installing the drive in other types of grounded
systems, contact your Yaskawa representative for instructions.
n
Guarding Against Harmful Materials
When installing IP00/Open Type enclosure drives, use an enclosure that prevents foreign material from entering the drive
from above or below.
u
Drive Derating Data
n
Rated Current Depending on Carrier Frequency
Increasing the carrier frequency above 2 kHz will reduce the rated output current of the drive.
NOTICE
Refer to the Z1000 User Manual (600 V models) TOEPYAIZ1U03 –
Drive Derating Data section
to assist in model selection
and adjustment when the application requires changing the drive carrier frequency from factory defaults.
To obtain instruction manuals for Yaskawa products access : http://www.yaskawa.com
i.10 European Standards
YASKAWA TOEP YAIZ1U 02B YASKAWA AC Drive – Z1000 Quick Start Guide
57