Setting
Function
Page
8
During baseblock (N.O.)
–
9
Frequency reference source
–
A
Run command source
–
A
HAND Mode
–
B
Torque detection 1 (N.O.)
–
C
Frequency reference loss
–
D
Braking resistor fault
–
E
Fault
–
F
Through mode
–
10
Minor fault
–
11
Fault reset command active
–
12
Timer output
–
13
Speed agree 2
–
14
User-set speed agree 2
–
15
Frequency detection 3
–
16
Frequency detection 4
–
17
Torque detection 1 (N.C.)
–
18
Torque detection 2 (N.O.)
19
Torque detection 2 (N.C.)
–
1A
During reverse
–
1B
During baseblock (N.C.)
–
1E
Restart enabled
–
1F
Motor overload alarm (oL1)
–
20
Drive overheat pre-alarm (oH)
–
22
Mechanical weakening detection
–
2F
Maintenance period
–
30
During torque limit
37
During frequency output
–
38
Drive enabled
–
39
Watt hour pulse output
–
3D
During speed search
–
3E
PID feedback low
–
3F
PID feedback high
–
40
Auto Mode
–
42
Pressure Reached
43
2 Motor Alternate
–
4A
During KEB Ride-Thru
–
4C
During fast stop
–
4D
oH Pre-alarm time limit
–
Braking transistor fault (rr)
–
4F
Braking resistor overheat (oH)
–
51
Sequence timer 1
–
Setting
Function
Page
52
Sequence timer 2
–
53
Sequence timer 3
–
54
Sequence timer 4
–
58
Underload detection
–
60
Internal cooling fan alarm
–
71
Secondary PI Feedback Low
–
72
Secondary PI Feedback High
–
80
Pump 2 Control
–
81
Pump 3 Control
–
82
Pump 4 Control
–
83
Pump 5 Control
–
84
Pump 6 Control
–
89
Output 1 Limit
–
8B
Lube Pump or Digital Output Delay
–
8F
Internal Fan On
–
91
Pump Fault
–
92
Transducer Loss
–
93
Setptoint Not Met
–
94
Loss of Prime
–
95
Volute Thermostat Fault
–
96
High Feedback
–
97
Low Feedback
–
98
Low Flow
–
99
Accum Level
–
9A
High Flow
–
9B
Low Water Level
–
9C
Low Suction
–
9D
High Suction
–
9E
Low PI Aux Level
–
9F
High PI Aux Level
–
A0
Water Loss/Suction Pressure/PI Aux Control
–
A1
Differential Detected
–
A2
Sleep Active
–
A3
Start Delay
–
A4
Pre-Charge
–
A5
Anti-Jam Active
–
A6
De-Scale Active
–
A7
Flow Rate Limit
A9
Thrust Mode
–
AA
Utility Start Delay
–
100 to
1AA
Function 0 to AA with inverse output
–
<1> Not available in models 4A0930 and 4A1200.
<2> Not available in models 2A0169 to 2A0415 and 4A0088 to 4A1200.
Setting 30: During Torque Limit
The output closes when the motor is operating at the torque limit specified by the L7-
oo
parameters or an analog input. This
setting can only be used in OLV control mode.
Setting 42: Pressure Reached
Note:
1.
Setting available in drive software versions PRG: 8552 and later.
2.
Setting not available in drive models 4A0930 and 4A1200.
i.5 Start-Up Programming and Operation
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide
61
Summary of Contents for CIMR-PW*A Series
Page 113: ......