TROUBLESHOOTING
WARNING!
Before performing any repair work, always remove the battery pack.
Caution!
Improper repairs can result in the product functioning unsafely. This endangers yourself and
your environment.
Faults which cannot be rectified with the aid of following table may be rectified by a specialist
company only (customer service center).
Please be aware that any improper repairs will also invalidate the warranty and additional
costs may be incurred.
Use only genuine spare parts. Only these spare parts are designed and suitable for the
product. The use of other spare parts not only voids the warranty, you can also endanger
yourself and your environment.
Fault
Possible cause
Solution
Product is not
running.
No electrical contact between the
trimmer and battery
Remove battery, check contacts and
reinstall the battery pack
The battery pack is depleted
Charge the battery pack
The two switch levers are not
depressed simultaneously
Depress the switch levers
on the front and rear handle
simultaneously
The battery pack is too hot
Remove the battery pack from the
tool and allow it to cool until the
temperature drops below 50°C
Blade Jammed
Remove battery pack full and then
wearing gloves removing the blade
jam ,replace the battery pack and
restart
Rear handle rotate lever or handle not
fully located into position
Recheck and posn where release
button is fully located
CE DECLARATION
To the provisions of Council Directives
We
SUMEC UK
Unit A&B Escrick Business Park Escrick, York YO19 6 FD/ United Kingdom
Declare that the product:
Declare that the product:
Description: 40V HEDGE TRIMMER
Model No. LH G60/ HT2340
Function: Trimming of hedges bushes and ornamental shrub
Complies with the essential health and safety requirements of the
following directives:
Machinery Directive 2006/42/EC
Electromagnetic Compatibility Directive 2014/30/EU
EC Directive 2011/65/EU and its amendment Directive (EU) 2015/863 (RoHS)
Noise Emission in the Environment by Equipment for Use Outdoors Directive
2000/14/EC amended by 2005/88/EC
Measured Sound Power Level: 92.65 dB (A) K=3.0dB(A)
Declared Guaranteed Sound Power Level: 96 dB (A)
Standards and technical specification referred to:
EN 60745-1:2009+A11:2010
EN 60745-2-15:2009+A11:2010
EN 60335-1:2012+A11
EN 60335-2-29: 2004+A2:2010
EN 55014-1:2017
EN 55014-2:2015
Authorized Signatory
Date: 24.03.2020
Signature:________________________
Place: York
Name: Mariana Hall
General Manager
SUMEC UK
Unit A&B Escrick Business Park Escrick
York YO19 6 FD, United Kingdom
Summary of Contents for LH G40
Page 2: ...2 3 A B b a d e c 1 2 3 4 5 6...
Page 3: ...4 5 C K E G I D L F H J...