SPECIFICATIONS
Marine Installation Manual - Volume 2
3YM30-5
3YM30
Air Intake and Exhaust Specifications
Alarm System Specifications
Parameter
Data
Exhaust Pipe Outer
Diameter Connection
50.8 mm
(2.0 in.)
Minimum Engine
Room Fresh Air
Exchanges
(Ventilator Capacity)
5.5 cu m/min.
(194.23 cu ft/min.)
Maximum Back
Pressure (measured
within 250 mm
[9.8 in.] of exhaust
manifold inlet)
1500 mmAq
14.7 kPa
(0.15 kgf/cm
2
)
Maximum Output
Exhaust
Temperature
(measured within
250 mm [9.8 in.] of
exhaust manifold
inlet)
600°C
(1112°F)
Maximum
Turbocharger Boost
Pressure
-
Maximum Engine
Room Ambient
Temperature
60°C
(140°F)
Parameter
Data
Coolant Alarm Switch
Operating
Temperature
ON:
93 - 97°C
(199.4 - 206.6°F)
OFF:
88 - 93°C
(190 - 199°F)
Lube Oil Switch
Operating Pressure
9.8 - 29.4 kPa
(1.43 - 4.27 psi)