![Yanmar 3YM30 Installation Manual Download Page 16](http://html.mh-extra.com/html/yanmar/3ym30/3ym30_installation-manual_905561016.webp)
3YM30
SPECIFICATIONS
3YM30-16
Marine Installation Manual - Volume 2
Controls
The 3YM30 uses a mechanical linkage to control
engine speed and marine gear shifting. Electric
stop solenoid is applied for engine stop.
Engine Speed Control (YPES-ML Fuel
Injection Pump
Recommended Remote Control Cable
Mechanical Controls (KM2P-1)
Recommended Remote Control Cable
Figure -11
Unit: mm
Parameter
Data
Shift Cable Stroke
76.2 mm
(3.0 in.)
Cable Connector Thread
Size
M5* P0.8
Parameter
Data
Shift Cable Stroke
76.2 mm
(3.0 in.)
Cable Connector Thread
Size
10-32 UNF
(See
Figure -11
)
Shifting Lever Force (Reference Value)
Shifting
Direction
Shift Lever
Position at
56 mm
(2.2 in.)
Remote
Control
Handle
Position at
170 mm
(cable length -
4 m
[157.5 in.])
Engaging
Force at
Engine 1000
min
-1
29.4 - 39.2 N
(3 - 4 kgf)
(6.6 - 8.8 lbf)
39.2 - 49.0 N
(4 - 5 kgf)
(8.8 - 11.0 lbf)
Disengaging
Force at
Engine 1000
min
-1
34.3 - 49.0 N
(3.5 - 5 kgf)
(7.7 - 11.0 lbf)
39.2 - 58.8 N
(4 - 6 kgf)
(11.0 - 13.2 lbf)
Disengaging
Force at
Engine 1000
min
-1
(KM2P-1 only)
39.2 - 49.0 N
(4 - 5 kgf)
(8.8 - 11.0 lbf)
49.0 - 58.8 N
(5 - 6 kgf)
(11 - 13.2 lbf)
39°
R56
10-32
UNF
Neutral
Forward
Reverse
25°
35.1
35.1
App
rox
.
70.2
39°
000
38
14