background image

If one of the batteries has failed or the trolling motor 

is running, the Trollbridge36® will not switch to par-

allel mode for charging. 

When charging is terminated the green LED

green LED

 will go 

off and the output reverts to 36-volts. This happens 

when the batteries get down below 13-volts. There is 

a time delay which can be canceled by operating the 

REMOTE button.

§ APPENDEX:

Shore power charger: 

Shore power charger: If your boat already has a multi output 

shore power charger it is compatible with the Trollbridge36 

however it does not make use of the equalizing feature of 

charging in parallel, which extends battery life. Preferably, all 3 

positive and all 3 negative charger outputs should be connected 

to the battery that has the yellow wire on it, making it into a 

single output charger .. 

A truck charging line

A truck charging line can be connected to the starting battery 

to charge all batteries. 

Radio Remote Button:

Radio Remote Button: If you need to run both motors at 

the same time or 36-volts is not available soon enough after 

charging has stopped, momentarily press the remote control 

button. This will set

set it in the 36-volt mode. To release

release 36-volt 

mode and resume charging, hold the remote button for 10 sec-

onds. Charging will only resume when all parameters are met 

and the trolling motor is not running.

Circuit breakers and fuses:

Circuit breakers and fuses: The positive feed to the trolling 

motor should always have a circuit breaker, 50-amp rating is 

typical. For ultimate protection and ABYC compliance, the 

Red, White, Blue and yellow wires to the battery positive termi-

nals could be fitted with disconnect switches and 100-amp slow 

blow fuses but if the wiring is well protected from accidental 

damage they are typically omitted.

WARRANTY VOID IF SUPPLIED CABLES ARE

WARRANTY VOID IF SUPPLIED CABLES ARE

MADE SHORTER

MADE SHORTER

 but OK to cut off and replace terminals. 

Email or phone technical support for trouble shooting and war-

ranty return authorization. 

TECHNICAL EMAIL QUERY

TECHNICAL EMAIL QUERY [email protected] 

or call 901-382-8888. 

This device complies with Part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) this device may 

not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause 

undesired operation.