27
CHECKWEIGHING FUNCTION
PRE-SETTING
Operation
Display
1 Press
to turn on the scale.
2 While pressing
, press
to enter the pre-setting mode.
3 Set the desired value 002 by pressing
or
.
4 Press
twice. The display goes to the parameter No. 03
(Buzzer setting). If you would like to sound the beep at
acceptable weight, enter “003” by pressing
or
.
000 No sound
001 Beep at under weight
002 Beep at over weight
003 Beep at acceptable weight
004 Beep at under & over weight
5 Press
until the display goes to the parameter No. 07
(Flash setting). If you would like to flash the weight display at
under weight, enter “001” by pressing
or
.
000 No Flicker
001 Flickers at under weight
002 Flickers at over weight
003 Flickers at acceptable weight
004 Flickers at under & over weight
005 Flickers with the parameter #03 (Beep) setting
6 Press
to store the setting value. The display goes to the
next parameter. To finish the pre-setting, keep pressing
.
The scale turns off.