10

Place the scale 

 
Make sure that the scale is placed on a leveled surface, or a correct measurement cannot be 
attained.  
Make sure that the scale is not shaky, which also results in an incorrect measurement. 
Do not place the scale on an inclined surface (if the inclination is beyond the adjustable range by the 
leveler). 
The bottom of the scale is equipped with 4 leveling legs with which the scale is adjusted to be on the 
level. Turn the leveling legs until the bubble locates at the center of the benchmark circle. It is 
recommended that the adjustment is conducted on a flat surface. Make sure that all the 4 legs 
equally touch the floor.   
 

 

 
 
 
 

 

How to interpret bubble position 

The length of the leg is adjusted by 
turning the leveling leg. 

The location of the bubble shows the 
horizontal status of the scale. 

Summary of Contents for UDS-1V-WP

Page 1: ...al DIGITAL UNIVERSAL SCALE UDS 1V WP OPERATION MANUAL Read this manual and keep it handy YAMATO SCALE CO LTD EXPORT 0703 ...

Page 2: ...descriptions in it to use Yamato s UDS 1V WP in the optimum condition for the longest life TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS 1 INSTRUCTIONS AND DIRECTIONS FOR USE 3 FUNCTIONS 4 PRODUCT PACKAGE 5 NAMES OF PARTS 5 TO KEEP THE SCALE WORKING EFFICIENTLY 6 INSTALLATION 7 DISPLAY AND KEYBOARD 11 CALIBRATION 12 BASIC OPERATION 13 TARE OPERATION 14 USER PARAMETER 15 HOW TO CHANGE USER PARAMETER 17...

Page 3: ...hibited Compulsion Denotes what must be followed NOTE Prior to use read carefully the following descriptions of Danger Warning and Caution to understand and comply with them Danger ToAvoid Electrical Shock Do not step on the power cable of anAC adaptor under the feet or other devices including a cart Connect or disconnect the AC adaptor securely by holding a plug section of the AC adaptor Do not p...

Page 4: ...ion Do Not Use Batteries Other than Specified Broken batteries or leakage may result in fire injury or taint damage Do Not Heat Batteries or Put in Fire or Water Otherwise batteries may burst Set Batteries Correctly as Instructed for Polarity Otherwise batteries may leak or burst Do Not Lick Batteries or Put in the Mouth Keep batteries out of the reach of small children Do Not Leave Run out Batter...

Page 5: ...enough to support the load 4 Use the equipment at the specified operation environment working temperature 10 C and 40 C 30 RH to 85 RH And avoid rapid change in temperature The inner pressure may cause instability of weight display For example if you move and use the scale in a place where the difference in temperature is more than 10 C use it after 5 minutes or more Dry batteries 1 Do not use alk...

Page 6: ...d by adding water wring it well and wipe out the dirt FUNCTIONS The UDS 1V WP has the following functions Use these functions in accordance with your purpose Function Application How to use the function Page Auto off Timer You want to shut down the scale automatically when operating by batteries The scale is set to shut down for 15 minutes after no use before shipment The setting can be changed fo...

Page 7: ...5 PRODUCT PACKAGE NAMES OF PARTS ...

Page 8: ...se the scale in clean water and wipe it thoroughly with a dry cloth 5 When disinfecting the pan and pan support with hypochlorous acid soak them in water whose hypochlorous acid concentration is 200 ppm or below for 5 to 10 minutes and then rinse in clean water and wipe them thoroughly with a dry cloth 6 When washing the pan and pan support with a neutral detergent apply a little neutral detergent...

Page 9: ...on the scale with a dry cloth 3 Turn the battery lid screw to open the battery lid 4 Remove the battery lid 5 Wipe off the water or dust around the battery box with a dry cloth 6 Set batteries correctly according to the polarity marks shown inside the battery box Incorrect set may damage the scale 7 Check the batteries are set firmly or the battery lid cannot be fully closed and its waterproof can...

Page 10: ...C adaptor Connection with an unsuitable adaptor may cause the damage 2 Batteries cannot be used at the same time make sure to remove all batteries and then use anAC adaptor 3 Remove the battery lid from the main body 4 Peel off the waterproof stickers attached to the battery lid andAC adaptor 5 Put theAC plug through the hole of battery lid 6 Firmly insert the plug of theAC adaptor into the jack 7...

Page 11: ...rned over Adrop and or excessive force may damage the scale 1 Turn over the scale 2 Wipe off the water or dust on the scale with a dry cloth 3 Remove the cover 4 Remove the dusts by fingers Carefully avoid excessive force on the rubber and not to damage the rubber 5 Hang the hook and close the cover ...

Page 12: ...ge by the leveler The bottom of the scale is equipped with 4 leveling legs with which the scale is adjusted to be on the level Turn the leveling legs until the bubble locates at the center of the benchmark circle It is recommended that the adjustment is conducted on a flat surface Make sure that all the 4 legs equally touch the floor How to interpret bubble position The length of the leg is adjust...

Page 13: ...erated The indicator blinks while the Fixed weighing function is set 4 The indicator is lit while the Grading function is operated The indicator blinks while the Grading function is set 5 The indicator is lit in accordance with the ongoing operations Total bar chart 15 segments KEY PART ON OFF key Turns the power on and turns the power off Tare key Tares off the weight on the scale pan Zero reset ...

Page 14: ...brate the scale any more It is possible to weigh an item after the scale is turned on When you calibrate the scale with weights outside the area 9 796 to 9 799 m s2 the procedures for electrical calibration as follows 1 Evaluate the setting value of the calibration area based on the above calculating formula and change the parameter 09 to the evaluated value 2 Calibrate the scale with standard wei...

Page 15: ...000 Confirm that the weight indication is accurate with standard weight BASIC OPERATION Operation Display 1 Press to turn on the scale The display shows zero after all the indicators blinks 2 When zero does not appear since the zero point is not correctly recognized Press Zero appears on the display 3 Place the item s on the pan The display shows the weight of the item The stable indicator is lit ...

Page 16: ...ntainer e g 25 g is shown on the display 2 Press after the stable indicator is lit The NET indicator is lit and the display shows zero 3 Start of weighing Place the item s in the container on the pan The display shows the net weight of the item e g 150 g 4 Cancellation of tare Remove the container from the pan The display shows the weight of the container as a negative number 5 Press The NET indic...

Page 17: ...ter no use 15 minutes after no use default 30 minutes after no use 60 minutes after no use 06 Auto tare at fixed weighing function 000 001 Auto tare OFF default Auto tare ON 07 Flicker of weight display 000 001 002 003 004 005 No flicker default Flickers at under weight Flickers at acceptable weight Flickers at over weight Flickers at under over weight Flickers with the parameter 03 settings 09 Gr...

Page 18: ...ng items on the pan set the parameter 4 at 001 Parameter 05 Auto off Timer The auto off timer can be selected by changing the setting value Parameter 06 Auto tare at fixed weighing function At fixed weighing function when you want to tare off a container weight automatically set the value at 001 When the scale displays 0 the weight of anything placed on the pan first time is tared off automaticall...

Page 19: ...ter setting mode 3 Press to move the parameter No from 01 to 05 Note When passing by 05 keep pressing until looping back to 05 4 Press or to change the value to 005 Note key move the value forward 1 key move the value backward 1 5 Press to store the setting value The display goes to the next parameter Note The setting value is not saved unless the display goes to the next parameter 6 Press for a w...

Page 20: ... 03 keep pressing until looping back to 03 4 Press or to change the value to 003 Note key move the value forward 1 key move the value backward 1 000 No sound 001 Beep at under weight 002 Beep at over weight 003 Beep at acceptable weight 004 Beep at under over weight 5 Press to store the setting value The display goes to the next parameter Note The setting value is not saved unless the display goes...

Page 21: ...looping back to 07 4 Press or to change the value to 003 Note key move the value forward 1 key move the value backward 1 000 No Flicker 001 Flickers at under weight 002 Flickers at over weight 003 Flickers at acceptable weight 004 Flickers at under over weight 005 Flickers with the parameter 03 Beep setting 5 Press to store the setting value The display goes to the next parameter Note The setting ...

Page 22: ...s 1 Target weight 2 Allowable weight Registered item No Maximum 99 items 0 g Target wt Allowable wt Full capacity CHECKWEIGHING OVER UNDER FUNCTION Application Checking the weight with bar charts How to weigh Set the lower limit and upper limit of the items on the scale and display the item s weight together with bar charts Features 1 You can know the acceptable range intuitively by displaying the...

Page 23: ... avoids man caused errors 2 Stating the rank in figures speeds up the sorting work Stored values 1 The lower limits of each rank 2 The upper limit of the upper rank Registered item No In case of sorting items to 2 ranks max 66 items are available In case of sorting items to 15 ranks max 12 items are available e g Sorting the item to 2 ranks 0 g The lower limit The lower limit The upper limit Full ...

Page 24: ...he parameter No 03 Buzzer setting If you would like to sound the beep at acceptable weight enter 003 by pressing or 000 No sound 001 Beep at under weight 002 Beep at over weight 003 Beep at acceptable weight 004 Beep at under over weight 5 Press 3 times The display goes to the parameter No 06 Auto Tare setting If you would like to tare the weight of container automatically enter 001 by pressing or...

Page 25: ...enter 001 by pressing or 000 No Flicker 001 Flickers at under weight 002 Flickers at over weight 003 Flickers at acceptable weight 004 Flickers at under over weight 005 Flickers with the parameter 03 Beep setting 7 Press to store the setting value The display goes to the next parameter To finish the pre setting keep pressing The scale turns off ...

Page 26: ...item number by pressing or e g Item No 13 4 Press The display switches to the setting screen of the target weight 5 Enter the target weight by pressing or Pressing changes the digit Pressing changes the value backward 1 Pressing changes the value forward 1 e g When the target weight is 100g enter 100 6 Press The display switches to the setting screen of the allowable weight 7 Enter the allowable r...

Page 27: ...er is tared off automatically NET indicator lights up 6 Place the item on the pan The display shows the weight to the target weight as a negative number The present level of weight is shown in the bar chart e g When the present weight is 55g for the target weight of 100g the display shows 45 7 Place the items on the pan until the display shows 0 The bar charts move to the lowest position of accept...

Page 28: ...shows the case that placing the items for 109g under the setting of target wt 100g and allowable wt 5g 10 Press to switch to the normal weighing mode after removing the items from the pan and the Center Zero indicator lights It is not available to switch over the weighing mode if the center of zero indicator does not light If you press again the display returns to the Fixed weighing operation PACK...

Page 29: ...eight 002 Beep at over weight 003 Beep at acceptable weight 004 Beep at under over weight 5 Press until the display goes to the parameter No 07 Flash setting If you would like to flash the weight display at under weight enter 001 by pressing or 000 No Flicker 001 Flickers at under weight 002 Flickers at over weight 003 Flickers at acceptable weight 004 Flickers at under over weight 005 Flickers wi...

Page 30: ...switches to the lower limit setting screen 5 To set the lower limit press to shift the digit ready for an entry Press or to set the value e g 100g 6 Press to save the value The display switches to the upper limit setting screen 7 Press to shift the digit ready for entry Press or to set the value e g 110g 8 When the incorrect values are set an error message appears When 0 is set to the lower limit ...

Page 31: ...net weight of the item is under the acceptable weight 100g to 110g the bar charts stop in the range of the under weight 6 When the net weight is in the range of acceptable weight the bar charts move to the range of the acceptable weight 7 When the net weight is heavier than the acceptable weight the bar charts show the overweight 8 Press to switch to the normal weighing mode after removing the ite...

Page 32: ... max 66 items can be registered The numbers of stored items are as below Value 002 003 004 005 006 007 008 009 010 011 012 013 014 015 No of ranks 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No of items 66 49 39 33 28 24 22 19 18 16 15 14 13 12 5 Press twice The display goes to the parameter No 04 Stability Restriction If you would like to sort the items only at stability enter 001 by pressing or 000 Gradin...

Page 33: ... on the scale 2 Confirm the pan is empty and then press briefly The display switches to the rank setting screen RANK blinks 3 Press or to chose the item number e g Item No 21 4 Press The display goes to the setting screen of rank 1 Set the lower limit of rank 1 Pressing changes the digit Pressing or changes the value 5 e g When set the rank 1 at 100g to 200g set the lower limit at 100 6 Press The ...

Page 34: ...lay switches to the operating screen of grading function OPERATION e g Recall the Item No 21 sorted to 2 ranks Rank1 100g to 200g Rank2 200g to 300g and start the grading operation Operation Display 1 Press to turn on the scale 2 Press briefly to recall the stored item No The display switches to the screen for the Grading Function RANK blinks 3 Press or to chose the saved item number e g Item No 2...

Page 35: ... stability restriction at 001 grading only at stability the display shows until the scale becomes stable and judges the rank 9 Press to switch to the normal weighing mode after removing the items from the pan and the center of zero indicator lights It is not available to switch over the weighing mode if the center of zero indicator does not light If you press again the display returns to grading o...

Page 36: ...atteries with new one The weight below zero This message appears when the weighed value is less than 5 divisions 5 g for the weighing capacity of 3000g Press If the stainless steel pan option has been removed set it on the scale again The overloading This message appears when the weighed value is over 5 divisions 3010g g for the weighing capacity of 3000g When the item is removed the display retur...

Page 37: ...tem from the pan and then press The initial error D Turned on the scale while the item was left on a pan And then removed it and pressed Make sure that nothing is left on the pan and turn on the scale again Trouble in electronic circuit This message appears when a trouble was detected in the electronic circuit Turn off the scale And reapply the power after a brief interval When the scale does not ...

Page 38: ...the data of items Lights up at Fixed weighing function Checkweighing function Flashes at setting the upper lower limits of items Lights up at Checkweighing function Grading function Flashes at setting the weight of each rank Lights up at Grading function 6 Functions Tare One touch tare Fixed weighing function Max 99 items can be registered Checkweighing function Max 99 items can be registered Grad...

Page 39: ...37 12 Power supply 6VDC 4 D size batteries orAC adaptor 13 Battery life Approx 1400 hours in continuous use alkaline dry battery 14 Power consumption Max 0 07W 15 Weight 3 7 kg 16 Outside dimensions ...

Page 40: ...YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Telephone 81 78 918 6157 Telefax 81 78 918 5552 PRINTED IN JAPAN ...