YCO-1125-03-13
PPC-300 & PPC-300D Operation Manual
II Description
4
Name and Function of Parts
1) ON/OFF Key
Press to turn the power on or to enter function mode. Hold to turn
power off.
2) Zero Key
Press to zero the display, select a digit, select the next parameter, or
store a setting. Simultaneously press the Zero and Tare keys to enter
user parameter mode.
3) Mode Toggle
Press the ON/OFF and Zero keys simultaneously to toggle between
function and normal weighing modes.
4) Tare Key
Press to tare off the current load or to increment a digit. Simultaneously
press the Zero and Tare keys to enter user parameter mode.
5) Net/Gross Key
Press to toggle between net and gross weight readings if a tare is en-
tered, or to decrement a digit.
6) Unit Toggle
Press the Net/Gross and Tare keys simultaneously to toggle through the
available weight units.
7) User Parameter Mode
Indicates that the scale is in user parameter mode.
8) Test Mode
In normal weighing mode: indicates that the scale is not configured to
be sealed for legal for trade operation.
In test mode: indicates that the scale is in test mode.
9) Battery Status
Indicates approximate remaining battery capacity in thirds.
10) Bubble Level
Use to level the scale.
11) Stable Indicator
Indicates the weight reading has stabilized.
12) Net Weight Indicator
Indicates the displayed weight is a net weight.
13) Center of Zero Indicator
Indicates the scale is at zero gross load.
14) Bar Chart
Indicates relationship between load and desired weight. The exact
meaning depends on the function mode in use.
15) Function Modes
CHECK - The scale is in Checkweighing function mode.
PACK - The scale is in Packing function mode.
RANK - The scale is in Grading function mode.
1
2
3
4
5
6
7
8
9
10
11
12 13
14
15
Summary of Contents for PPC-300