mod. MS1400
–
cod. 93249
14
5. OPERATING INSTRUCTIONS
Before any start-up make sure:
• That the voltage of the mains corresponds to that of the nameplate of the machine.
• Use suitable extension cables. the extension should
have a ø 1.5 mm2, if the extension is with cable
reel, unroll the entire cable before starting the machine.
Read the following instructions carefully.
Electronic soft-start
Ensures maximum speed is reached smoothly without sudden shocks when the tool is switched on
Start - stop 2
- Press the on / off lock button
- Press the trigger of the switch to turn on
- Release the switch trigger to turn off
Continuous use 3
-Press the on / off lock button to release the switch trigger
-Then press the switch trigger to turn on
-Turn on the lock button again for continuous use
Speed selection 4
The necessary rotation frequency is adjusted in advance by turning the regulator disc in the direction
of the arrow or towards the “+” sign to increase the number of revol
utions, and in the opposite
direction to the arrow, or towards the “
-
” sign for reduction. This ensures an optimal operating regime.
Attachment or change of the whip 5
Remove the plug from the socket, if inserted. First fix the two parts that make up the hose E1 and E2
by screwing them together. Then screw the whisk E to the connection on the mixer using 2 wrenches
as shown in the figure. To disassemble the whisk proceed in reverse order.
Advice
Make sure the mixing container is placed firmly on the floor
Immerse the whisk in the substance to be mixed.
Set wheel C to low speed.
Turn on the instrument
Gradually increase the mixing speed by turning wheel C to the desired maximum
(so that the substance does not splash and the tool does not overload)
Switch off the instrument with the whisk in the mixing container
The agitator continues to run for some time after switching off. If the rotating agitator touches a
surface, it can cause a reverse thrust.
Always clean the mixer after use.
Warning! Hold the instrument firmly with both hands and assume a safe position
Maintenance and repair
Unplug the machine prior to any procedures on the power tool.
Your power tool requires no additional lubrication or maintenance. Always store your power tool in
a dry place. If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Motor housing as free dirt and dust as possible. Clean the unit by rubbing it with a clean cloth or blow
it clean using low- pressure compressed air.
Always clean the unit immediately after using it.
Do not using cleaners or solvents, this will attack the aplastic parts in the unit.
You must also ensure that water cannot get into the inside of the unit.
6. WARRANTY
This power tool is guaranteed for a period of 24 months, from possible defects of manufacturing.
Summary of Contents for MS1400
Page 3: ...mod MS1400 cod 93249 3 5...
Page 16: ...mod MS1400 cod 93249 16...