8
DP-6100 GP
Technical Manual
Removing Load Cell:
1)
Unplug power supply or remove batteries.
2)
Remove platform:
To remove, unscrew (2) Sealing Screws and (2)
Phillips head screws from front and back of
platform.
3)
Remove (4) Load Cell Bolts which attach Upper
Spider to Load Cell.
Upper Spider is the frame to which platform is
attached.
4)
Upper Spider is now free to remove.
5)
Remove (4) Load Cell Bolts which attach Load Cell
to Lower Spider.
Note: Lower Spider Load Cell Bolts are longer.
6)
Remove bolt which holds Ground Wire (from load
cell) against Lower Spider.
Note: Bolt does not need to be completely
removed.
Load cell in now free from upper and lower
spider. The following steps remove load cell
wiring harness from column and indicator
housing.
7)
Remove Column Cover:
Column Cover is located on back of indicator.
Remove (2) screws and cover.
Note position of rubber gasket that is reveal for
proper installation in future.
Load Cell Bolt
Load Cell Bolt
Ground Wire
Upper Spider
Lower Spider
Cover
Screws
REPLACING LOAD CELL