6
DP-6100 GP
Technical Manual
Keyword parameters must be checked and/or modified if CPU board (or A/D board) is replaced.
Note: If you replace a version V1.00G CPU board with a version V1.01(A, B, C) CPU board, the
parameters must be modified as shown in Appendix.
To modify Keyword Parameters, perform the following procedure.
1)
Enter TEST MODE (refer to page 4).
2)
Press
kg
lb
three times. Display will indicate “Keyword Parameter Setup" mode >>
3)
Press
SETTING
to enter setup. (Mode flow chart is on page 5 for further understanding.)
4)
First Keyword Parameter will be displayed, "30.032". The two digits left of the decimal point is the
"Keyword". The three digits right of the decimal point is the Keyword's "Parameter" (see
Figure 4
).
5)
Check and modify Keyword Parameters as necessary. Keyword Parameter Values are listed in
Appendix A.
a)
To increase "Keyword", press
SETTING
.
To decrease, press and hold
SETTING
, then press
CLEAR
.
b)
To increase "Parameter", press
kg
lb
. To decrease, press
N
G
.
Reminder:
Keyword Parameter Values are listed in Appendix A.
Important: After "Parameter" is modified, you must advance to next "Keyword" by
pressing
SETTING
. Otherwise, modification will not be saved!
c)
Repeat steps
5 a)
&
b)
until all Keyword Parameters are check and/or modified.
6)
When Keyword Parameter modification is complete, press
. This moves you into
"Supplementary Keyword Parameter Setup" >>
a)
To skip "Supplementary" setup, press
.
b)
To enter setup, press
SETTING
. Check and modify using procedure above and Appendix B.
Note: Procedure is same, except display lacks decimal point (see
Figure 5
).
When modification is complete, press
.
6)
Congratulations, Keyword Parameter Setup is complete!
Keyword
Parameter
Figure 4
Keyword
Parameter
Figure 5
MODIFYING KEYWORD PARAMETERS