background image

YCO-1047-07-04

PPC-200(W)

            Operation Manual

1)   Begin with no load on the scale, the display reading zero, and 

the center zero and stable indicators lit.  The small up and down 
ar row heads on the right side of the display indicate that the over 
and under setpoints, re spec tive ly, have been set.

2)   Place the item(s) to be weighed on the scale platform.  If the item 

weighs less than the under setpoint, the large under arrow will 
appear.

3)   If the item weighs from the lower setpoint to the upper setpoint, 

in clu sive, the accept bullseye will appear.

4)   If the item weighs more than the upper setpoint, the large over 

arrow will appear. 

4

         III.H.2 

Gross Weighing

1)   Begin with no load on the scale, the display reading zero, and the 

center zero and stable indicators lit.

2)   Place the item(s) to weighed on the scale platform.  The weight 

displayed will be the gross weight.

III Directions for Use

III.H   Weighing

         III.H.1 

Using the Under/Over Indicator

Summary of Contents for Accu-weigh PPC-200W

Page 1: ...TO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 5...

Page 2: ...weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the plat form or drop it...

Page 3: ...the Scale 2 C Turning the Scale On and Off 2 D Checking the Battery Level 2 E Zero the Display 2 F Switching Between LB and KG 2 G Setting the Over Under Indicator 3 H Weighing 4 1 Using the Over Und...

Page 4: ...ry Cover Tighten securely to maintain washdown seal 14 Outlet of AC adaptor cable Use of an AC adapter voids washdown seal 15 Levelling Legs Rotate to level the scale Fig 1 Front side of the scale Fig...

Page 5: ...ecurely into the jack Do not washdown the scale if an AC adaptor is in use or if the washdown plug has been removed from the AC jack III B Leveling the Scale Place the scale on a at and level surface...

Page 6: ...indicated as under 6 Press and hold the key and push the key Yellow Cor ners This saves the lower limit and moves to the upper limit 7 Press the key to select the digit you want to change 8 Press the...

Page 7: ...ess than the under setpoint the large under arrow will appear 3 If the item weighs from the lower setpoint to the upper setpoint inclusive the accept bullseye will appear 4 If the item weighs more tha...

Page 8: ...eight of the item s and the container Press the key again to return to the net weight 5 To return to gross weighing mode remove all items from the scale platform and press the key III H 4 Batching 1 B...

Page 9: ...nd to enter User Parameter Mode The scale will indicate a keyword fol lowed by it s value 2 To select the desired keyword use the keys as follows increase keyword by one decrease keyword by one Note U...

Page 10: ...t and the indicator will move to the under range 2 Use the and keys to align the indicator with the low end of the under range 3 Press the key The indicator will move to the over range 4 Use the and k...

Page 11: ...ntil the entire number is set 5 Press the key again to save the displayed under setpoint and to display the current over setpoint 6 Press the key to select the digit you want to change 7 Press the or...

Page 12: ...ayed It is usually displayed when the plat form is removed or has something wedged under it 4 Initial error on startup When the initial weight is heavier than the permissible zeroing range and the key...

Page 13: ...weight gross weight 1 batch 002 Net weight tare weight gross weight 3 batches 003 Display content 1 batch 004 Serial printer format 1 batch 05 000 Communication speed 000 9600 bps 001 600 bps 002 1200...