6 - 46
FI
AIR INDUCTION SYSTEM
CHECKING THE PRESSURE REGULATOR
1. Check:
• pressure regulator
Damage
→
Replace.
EAS00510
CHECKING THE AIR INDUCTION SYSTEM
1. Check:
• hoses
Loose connection
→
Connect properly.
Cracks/damage
→
Replace.
• pipes
Cracks/damage
→
Replace.
2. Check:
• fiber reed
• fiber reed stopper
• reed valve seat
Cracks/damage
→
Replace the reed valve.
3. Check:
• air cut-off valve
Cracks/damage
→
Replace.