8 - 60
–
+
ELEC
IMMOBILIZER SYSTEM
YES
NO
YES
NO
4. Voltage
• Connect the pocket tester (DC 20 V) to the
immobilizer unit coupler as shown.
Positive tester probe
→
red/white
1
Negative tester probe
→
black
2
• Set the main switch to “ON”.
• Measure the voltage (12 V) between red/
white and black on the immobilizer unit
coupler.
• Is the voltage within specification?
The wiring circuit
from the main switch
to the immobilizer
unit is faulty and
must be repaired.
B
BB
Y/L G/L R/W
R/G
R/G B2
R/W Lg Y/L
B
2
1
5. Voltage
• Connect the pocket tester (DC 20 V) to the
immobilizer unit coupler as shown.
Positive tester probe
→
green/blue
1
Negative tester probe
→
black
2
• Set the main switch to “ON”.
• Measure the voltage (2.6 V) between
green/blue and black on the immobilizer
unit coupler.
• Is the voltage within specification?
The wiring circuit
from the immobilizer
unit to the meter
assembly is faulty
and must be
repaired.
Replace the immobi-
lizer unit.
B
BB
Y/L G/L R/W
R/G
R/G B2
R/W Lg Y/L
B
2
1
Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys