3 - 59
CHK
ADJ
CHECKING THE FUSES
2. Check:
• fuse
1
• fuse box 1
2
• fuse box 2
3
▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼▼▼
a. Connect the pocket tester to the fuse and
check the continuity.
NOTE:
_
Set the pocket tester selector to “
Ω
×
1”.
b. If the pocket tester indicates “
∞
”, replace
the fuse.
▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲▲▲
3. Replace:
• blown fuse
▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼▼▼
a. Set the main switch to “OFF”.
b. Install a new fuse of the correct amperage
rating.
c. Set on the switches to verify if the electrical
circuit is operational.
d. If the fuse immediately blows again, check
the electrical circuit.
Pocket tester
90890-03112
Fuses
Amperage
rating
Q’ty
Main
30 A
1
Headlight
20 A
1
Signaling system
10 A
1
Ignition
10 A
1
Fuel injection system
10 A
1
Parking lighting system
10 A
1
Radiator fan motor
7.5 A
1
Backup (immobilizer
unit, meter assembly)
10 A
1
Reserve
30 A
1
Reserve
20 A
1
Reserve
10 A
1
Reserve
7.5 A
1
2
3
1
Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys