background image

 

6   

 

XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual

 

Controls and Functions

 

 

Front Panel

 

1

 

POWER switch and indicator

 

Press this to turn the power on or off. The POWER/
STANDBY indicator lights up in green when the power 
is ON. If the amplifier has been set to STANDBY mode, 
the indicator is lit in orange.

 

2

 

TEMP indicator

 

Lights up red if the heat sink temperature exceeds 85°C 
(185°F). 

 

3

 

PROTECTION indicator

 

When the protection system is active, the PROTECT 
indicator light up in red and the speakers are automati-
cally disconnected from the amplifier’s outputs. The 
protection system activates in the following situations:

 

When the amplifier is turned on

 

The protection system activates for approximately 
three seconds when the amplifier is turned on. After 
three seconds, the protection system deactivates auto-
matically and the amplifier is ready for normal opera-
tion.

 

If a DC voltage is detected at the amplifier’s 
outputs

 

XP7000/5000: Power shut down and the indicator is 
not lit.
XP3500/2500/1000: The protection system is active. 
Once the DC voltage problem is corrected, the protec-
tion system deactivates automatically and the ampli-
fier is ready for normal operation.

 

If the amplifier overheats

 

When overheating occurs, the PROTECT/MUTE 
indicator lights. You should immediately turn off the 
amplifier and allow it time to cool down. See the Pre-
cautions section of this Owner’s Manual for ways to 
prevent the amplifier from overheating.

 

4

 

CLIP indicator

 

Lights up red when the output signal distortion on the 
corresponding channel rises above 1% — indicating 
that “clipping” has occurred bacause the signal level is 
too high.

 

5

 

SIGNAL indicator

 

Lights up green when the corresponding channel’s out-
put level exceeds 2 Vrms (equivalent to 1/2 W into an 8 

 

 

 load, or 1 W into a 4 

 

 

 load).

 

6

 

Volume control knobs

 

Each control knob adjusts the volume of the corre-
sponding channel, in 31 steps from -

 

 

 dB to 0 dB.

 

* If you wish to lock in the knob settings, you can 

fasten the supplied security cover over the 
knobs so that the settings will not be disturbed.

 

 

How to install the security cover

 

(1) Use the supplied hex wrench to remove the four 

attachment screws from the amplifier.

(2) Adjust the security cover to the position of screw 

holes. Fasten it into place using the same screws.

 

7

 

Air intakes

 

The amplifier uses forced-air cooling. The cooling fans 
draw air in from the front and exhaust it through the 
rear. Please be sure that you do not block the air intakes 
or exhaust vents.

 

* The fans do not come on at initial power-on, but 

will switch on automatically when the temperature 
of the heat sink rises above 50°C (122°F). The fan 
speed will then vary automatically as the tempera-
ture changes.

* The illustration shows model XP7000.

1

7

6

2

3

7

4

5

Front

Rear

Air 

exhaust

Air 

intake

Summary of Contents for XP7000

Page 1: ...POWER AMPLIFIER OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE INSTRUCCIONES ES FR DE EN English Deutsch Fran ais Espa ol...

Page 2: ...oint where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold...

Page 3: ...ving the device remove all connected cables When setting up the product make sure that the AC outlet you are using is easily accessible If some trouble or malfunction occurs immediately turn off the p...

Page 4: ...onents Illustrations in this manual are for explanatory purposes only and may not match the actual appearance of the product during operation Company names and product names used in this Owner s Manua...

Page 5: ...tep Volume control are provided for each channel A PROTECTION indicator that shows the state of various protection systems power on off detection output protection DC detection a TEMP indicator that i...

Page 6: ...turn off the amplifier and allow it time to cool down See the Pre cautions section of this Owner s Manual for ways to prevent the amplifier from overheating 4 CLIP indicator Lights up red when the ou...

Page 7: ...itch STEREO mode In STEREO mode channels A and B are completely independent PARALLEL mode In PARALLEL mode the channel A input signal is sent both to the channel A power amp and the channel B power am...

Page 8: ...The volume controls on the front panel A and B let you control the volume of each channel independently 5 way binding post Speakon connector Parallel Mode Set the Mode switch to PARALLEL to use the u...

Page 9: ...the unit as a high power mono amplifier The volume control A on the front panel A lets you control the volume 5 way binding post Speakon connector Note In this case the loads for A and B are directly...

Page 10: ...kers at 15 W for 315 W The total is 625 W per channel Be sure to use speakers that support the XP7000 s line out voltage of 70 V The XP3500 enables you to connect in bridge fashion multiple high imped...

Page 11: ...eaker terminals Tighten the terminals to securely clamp the wires Refer to page 8 for speaker polarities Be sure that the bare wire ends do not jut out from the terminals and touch the chassis 4 Reatt...

Page 12: ...around the amplifier The TEMP indicator lights up to indicate tem perature warning PROTECTION indica tor lights The heat sink temperature has exceeded 90 C 194 F Check the amplifier ventilation condi...

Page 13: ...390 W 4 STEREO 590 W 590 W 590 W 590 W 590 W 590 W 8 BRIDGED 1180 W 1180 W 1180 W 20 20 kHz THD N 0 1 8 STEREO 350 W 350 W 350 W 350 W 350 W 350 W 4 STEREO 450 W 450 W 435 W 435 W 450 W 450 W 8 BRIDGE...

Page 14: ...26 dB position 13 7 dBu 120V 240V 13 6 dBu 230V 12 2 dBu 10 7 dBu 9 2 dBu 5 2 dBu 32 dB position 7 7 dBu 120V 240V 7 6 dBu 230V 6 2 dBu 4 7 dBu 3 2 dBu 0 8 dBu Maximum Input Voltage MIN 22 dBu Input...

Page 15: ...to GND 4 REMOTE CONTROL NC 5 NC 6 MUTE CH B MUTE On Control Connect the pin to GND max 1mA flows MUTE Off Control Open the pin 5V applied 7 MUTE CH A 8 MONITOR NC 9 NC 10 PROTECTION MUTE STATUS CH B P...

Page 16: ...CTION SIGNAL CLIP LIMIT RE GR GR RE RE BSIG TEMPERATURE SENSOR TEMPERATURE SENSOR PROTECTION CIRCUIT FAN CONTROL CIRCUIT POWER ON DETECT CIRCUIT LIMITER LIMITER PA 5V 5 B 15 15 B 24 24 15V 15V 15V U A...

Page 17: ...CIRCUIT CH B TEMP PROTECTION SIGNAL CLIP LIMIT RE GR GR RE RE SP RELAY BSIG TEMPERATURE SENSOR LED DRIVE CIRCUIT FAN CONTROL CIRCUIT PROTECTION CIRCUIT LIMITER LIMITER PA 24 24 B B 15 15 15V Thermal...

Page 18: ...0V 230 240V In Out Dissipated Btu h kcal h standby 0 08 0 04 5 0 5 17 4 idle 1 0 0 5 35 0 35 119 30 1 8 power 8 ch 4 0 2 2 277 131 146 499 126 4 ch 6 2 3 4 436 188 249 848 214 1 3 power 8 ch 9 3 5 1 6...

Page 19: ...XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual 19 Memo...

Page 20: ...20 XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual Memo...

Page 21: ......

Page 22: ...S G Pro Audio Division 2005 Yamaha Corporation 305POAPx x 01E0 Printed in Vietnam WF37200 Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manua...

Reviews: