background image

XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual   

13

Specifications

General Specifications

XP7000

120 V

230 V

240 V

Output Power

1 kHz
THD+N= 1 % 

/STEREO

MIN

750 W + 750 W

750 W + 750 W

750 W + 750 W

/STEREO

1100 W + 1100 W

1100 W + 1100 W

1100 W + 1100 W

/BRIDGED 

2200 W

2200 W

2200 W

20 –20 kHz
THD+N= 0.1 % 

/STEREO

700 W + 700 W

690 W + 690 W

700 W + 700 W

/STEREO

950 W + 950 W

950 W + 950 W

950 W + 950 W

70 V/STEREO RL=8 

625 W + 625 W

625 W + 625 W

625 W + 625 W

/BRIDGED

1900 W

1900 W

1900 W

1 kHz
20mS nonclip

/STEREO

1600 W + 1600 W

1600 W + 1600 W

1600 W + 1600 W

/BRIDGED

3200 W

3200 W

3200 W

SN Ratio

20Hz-20kHz

(DIN AUDIO)

MIN

104 dB

Power 
Consumption

Standby / Idle

5 W / 35 W

1/8 (4 

/Pink noise)

650 W

650 W

650 W

XP5000

120 V

230 V

240 V

Output Power

1 kHz
THD+N= 1 % 

/STEREO

MIN

525 W+525 W

525 W+525 W

525 W+525 W

/STEREO

750 W+750 W

750 W+750 W

750 W+750 W

/BRIDGED

1500 W

1500 W

1500 W

20 –20 kHz
THD+N= 0.1 % 

/STEREO

500 W+500 W

500 W+500 W

500 W+500 W

/STEREO

700 W+700 W

700 W+700 W

700 W+700 W

/BRIDGED

1400 W

1400 W

1400 W

1 kHz
20mS nonclip

/STEREO

1300 W+1300 W

1300 W+1300 W

1300 W+1300 W

/BRIDGED

2600 W

2600 W

2600 W

SN Ratio

20Hz-20kHz

(DIN AUDIO)

MIN

103 dB

Power 
Consumption

Standby /idle

5 W / 35 W

1/8 (4 

/Pink noise)

500 W

500 W

500 W

XP3500

120 V

230 V

240 V

Output Power

1 kHz
THD+N= 1 % 

/STEREO

MIN

390 W+390 W

390 W+390 W

390 W+390 W

/STEREO

590 W+590 W

590 W+590 W

590 W+590 W

/BRIDGED 

1180 W

1180 W

1180 W

20 –20 kHz
THD+N= 0.1 % 

/STEREO

350 W+350 W

350 W+350 W

350 W+350 W

/STEREO

450 W+450 W

435 W+435 W

450 W+450 W

/BRIDGED 

900 W

870 W

900 W

100 V/BRIDGED RL=16 

625 W

625 W

625 W

1 kHz
20mS nonclip

/STEREO

1000 W+1000 W

925 W+925 W

1000 W+1000 W

/BRIDGED

2000 W

1850 W

2000 W

SN Ratio

20Hz-20kHz

(DIN AUDIO)

MIN

102 dB

Power 
Consumption

Standby / idle

5 W / 30 

1/8 (4 

/Pink noise)

450 W

450 W

450 W

XP2500

120 V

230 V

240 V

Output Power

1 kHz
THD+N= 1 % 

/STEREO

MIN

275 W+275 W

275 W+275 W

275 W+275 W

/STEREO

390 W+390 W

390 W+390 W

390 W+390 W

/BRIDGED

780 W

780 W

780 W

20 –20 kHz
THD+N= 0.1 % 

/STEREO

250 W+250 W

250 W+250 W

250 W+250 W

/STEREO

300 W+300 W

295 W+295 W

300 W+300 W

/BRIDGED

600 W

590 W

600 W

1 kHz
20mS nonclip

/STEREO

650 W+650 W

650 W+650 W

650 W+650 W

/BRIDGED

1300 W

1300 W

1300 W

SN Ratio

20Hz-20kHz

(DIN AUDIO)

MIN

100 dB

Power 
Consumption

Standby / idle

5 W / 25 W

1/8 (4 

/Pink noise)

320 W

320 W

320 W

XP1000

120 V

230 V

240 V

Output Power

1 kHz
THD+N= 1 % 

/STEREO

MIN

135 W+135 W

125 W+125 W

120 W+120 W

/STEREO

165 W+165 W

155 W+155 W

155 W+155 W

/BRIDGED

330 W

310 W

310 W

20 –20 kHz
THD+N= 0.1 % 

/STEREO

110 W+110 W

100 W+100 W

100 W+100 W

/STEREO

125 W+125 W

115 W+115 W

110 W+110 W

/BRIDGED

250 W

230 W

220 W

1 kHz
20mS nonclip

/STEREO

250 W+250 W

250 W+250 W

250 W+250 W

/BRIDGED

500 W

500 W

500 W

SN Ratio

20 Hz-20 kHz

(DIN AUDIO)

MIN

96 dB

Power 
Consumption

Standby / idle

5 W / 20 W

1/8 (4 

/Pink noise)

170 W

170 W

170 W

Summary of Contents for XP7000

Page 1: ...POWER AMPLIFIER OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE INSTRUCCIONES ES FR DE EN English Deutsch Fran ais Espa ol...

Page 2: ...oint where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold...

Page 3: ...ving the device remove all connected cables When setting up the product make sure that the AC outlet you are using is easily accessible If some trouble or malfunction occurs immediately turn off the p...

Page 4: ...onents Illustrations in this manual are for explanatory purposes only and may not match the actual appearance of the product during operation Company names and product names used in this Owner s Manua...

Page 5: ...tep Volume control are provided for each channel A PROTECTION indicator that shows the state of various protection systems power on off detection output protection DC detection a TEMP indicator that i...

Page 6: ...turn off the amplifier and allow it time to cool down See the Pre cautions section of this Owner s Manual for ways to prevent the amplifier from overheating 4 CLIP indicator Lights up red when the ou...

Page 7: ...itch STEREO mode In STEREO mode channels A and B are completely independent PARALLEL mode In PARALLEL mode the channel A input signal is sent both to the channel A power amp and the channel B power am...

Page 8: ...The volume controls on the front panel A and B let you control the volume of each channel independently 5 way binding post Speakon connector Parallel Mode Set the Mode switch to PARALLEL to use the u...

Page 9: ...the unit as a high power mono amplifier The volume control A on the front panel A lets you control the volume 5 way binding post Speakon connector Note In this case the loads for A and B are directly...

Page 10: ...kers at 15 W for 315 W The total is 625 W per channel Be sure to use speakers that support the XP7000 s line out voltage of 70 V The XP3500 enables you to connect in bridge fashion multiple high imped...

Page 11: ...eaker terminals Tighten the terminals to securely clamp the wires Refer to page 8 for speaker polarities Be sure that the bare wire ends do not jut out from the terminals and touch the chassis 4 Reatt...

Page 12: ...around the amplifier The TEMP indicator lights up to indicate tem perature warning PROTECTION indica tor lights The heat sink temperature has exceeded 90 C 194 F Check the amplifier ventilation condi...

Page 13: ...390 W 4 STEREO 590 W 590 W 590 W 590 W 590 W 590 W 8 BRIDGED 1180 W 1180 W 1180 W 20 20 kHz THD N 0 1 8 STEREO 350 W 350 W 350 W 350 W 350 W 350 W 4 STEREO 450 W 450 W 435 W 435 W 450 W 450 W 8 BRIDGE...

Page 14: ...26 dB position 13 7 dBu 120V 240V 13 6 dBu 230V 12 2 dBu 10 7 dBu 9 2 dBu 5 2 dBu 32 dB position 7 7 dBu 120V 240V 7 6 dBu 230V 6 2 dBu 4 7 dBu 3 2 dBu 0 8 dBu Maximum Input Voltage MIN 22 dBu Input...

Page 15: ...to GND 4 REMOTE CONTROL NC 5 NC 6 MUTE CH B MUTE On Control Connect the pin to GND max 1mA flows MUTE Off Control Open the pin 5V applied 7 MUTE CH A 8 MONITOR NC 9 NC 10 PROTECTION MUTE STATUS CH B P...

Page 16: ...CTION SIGNAL CLIP LIMIT RE GR GR RE RE BSIG TEMPERATURE SENSOR TEMPERATURE SENSOR PROTECTION CIRCUIT FAN CONTROL CIRCUIT POWER ON DETECT CIRCUIT LIMITER LIMITER PA 5V 5 B 15 15 B 24 24 15V 15V 15V U A...

Page 17: ...CIRCUIT CH B TEMP PROTECTION SIGNAL CLIP LIMIT RE GR GR RE RE SP RELAY BSIG TEMPERATURE SENSOR LED DRIVE CIRCUIT FAN CONTROL CIRCUIT PROTECTION CIRCUIT LIMITER LIMITER PA 24 24 B B 15 15 15V Thermal...

Page 18: ...0V 230 240V In Out Dissipated Btu h kcal h standby 0 08 0 04 5 0 5 17 4 idle 1 0 0 5 35 0 35 119 30 1 8 power 8 ch 4 0 2 2 277 131 146 499 126 4 ch 6 2 3 4 436 188 249 848 214 1 3 power 8 ch 9 3 5 1 6...

Page 19: ...XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual 19 Memo...

Page 20: ...20 XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual Memo...

Page 21: ......

Page 22: ...S G Pro Audio Division 2005 Yamaha Corporation 305POAPx x 01E0 Printed in Vietnam WF37200 Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manua...

Reviews: