background image

 

XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual

 

   5

 

Introduction

 

Thank you for purchasing a Yamaha XP7000, XP5000, XP3500, XP2500, XP1000 Series Power Ampli-
fier.
The XP Series of power amplifiers was developed from Yamaha’s wealth of experience in building PA 
equipment and its tradition of careful attention to every detail of circuit design. These power amplifiers 
feature high power — thanks to EEEngine (Energy Efficient Engine) technology — and superb quality 
together with superior reliability and stability, guaranteeing the highest possible audio performance.

 

Main features include

 

• Three modes are provided to support a broad range of applications: STEREO mode which can be driven by two 

independent sources, PARALLEL mode in which a monaural source drives both channels, and BRIDGE mode in 
which the two internal amps function as a single high-power mono amp.

• Balanced XLR connector and Euroblock connector inputs, and Speakon connector and five-way binding post 

outputs are provided.

• A high pass filter switch that enables selection of the cutoff frequency (20Hz or 55Hz).
• Signal indicator, clip indicator and sophisticated dB step Volume control are provided for each channel.
• A PROTECTION indicator that shows the state of various protection systems (power on/off detection, output 

protection, DC detection), a TEMP indicator that indicates heat sink overheating, and a POWER/STANDBY 
indicator that indicates the power status.

• Variable-speed low-noise fans ensure high reliability.
• The XP7000 enables parallel connection of multiple high-impedance speakers that support 70V line output.
• The XP3500 enables parallel connection of multiple high-impedance speakers that support 100 V line output.
• A MONITOR/REMOTE terminal that allows monitoring or control over the amplifier via a network.

 

This Owner’s Manual applies to the XP7000, XP5000, XP3500, XP2500, XP1000 power amplifier. In 
order to take full advantage of your power amplifier and enjoy long and trouble-free operation, please 
read this Owner’s Manual carefully before using your Power Amplifier.

 

Contents

 

Controls and Functions............................6

 

Front Panel ......................................................... 6
Rear Panel  ......................................................... 7

 

Speaker Connections  .............................. 8

 

Stereo Mode ....................................................... 8
Parallel Mode  ..................................................... 8
Bridged Mode
(use as high-power mono amplifier) ................... 9

 

High-impedance speaker connections .. 10

Connection ............................................. 11

 

Using a Euroblock connector  ........................... 11
Speaker Connection ......................................... 11

 

Troubleshooting ..................................... 12

Specifications ......................................... 13

 

General Specifications  ..................................... 13
MONITOR/REMOTE PIN layout  ...................... 15
Dimensions ...................................................... 15
Block Diagram .................................................. 16
Current Draw .................................................... 18

Summary of Contents for XP7000

Page 1: ...POWER AMPLIFIER OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE INSTRUCCIONES ES FR DE EN English Deutsch Fran ais Espa ol...

Page 2: ...oint where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold...

Page 3: ...ving the device remove all connected cables When setting up the product make sure that the AC outlet you are using is easily accessible If some trouble or malfunction occurs immediately turn off the p...

Page 4: ...onents Illustrations in this manual are for explanatory purposes only and may not match the actual appearance of the product during operation Company names and product names used in this Owner s Manua...

Page 5: ...tep Volume control are provided for each channel A PROTECTION indicator that shows the state of various protection systems power on off detection output protection DC detection a TEMP indicator that i...

Page 6: ...turn off the amplifier and allow it time to cool down See the Pre cautions section of this Owner s Manual for ways to prevent the amplifier from overheating 4 CLIP indicator Lights up red when the ou...

Page 7: ...itch STEREO mode In STEREO mode channels A and B are completely independent PARALLEL mode In PARALLEL mode the channel A input signal is sent both to the channel A power amp and the channel B power am...

Page 8: ...The volume controls on the front panel A and B let you control the volume of each channel independently 5 way binding post Speakon connector Parallel Mode Set the Mode switch to PARALLEL to use the u...

Page 9: ...the unit as a high power mono amplifier The volume control A on the front panel A lets you control the volume 5 way binding post Speakon connector Note In this case the loads for A and B are directly...

Page 10: ...kers at 15 W for 315 W The total is 625 W per channel Be sure to use speakers that support the XP7000 s line out voltage of 70 V The XP3500 enables you to connect in bridge fashion multiple high imped...

Page 11: ...eaker terminals Tighten the terminals to securely clamp the wires Refer to page 8 for speaker polarities Be sure that the bare wire ends do not jut out from the terminals and touch the chassis 4 Reatt...

Page 12: ...around the amplifier The TEMP indicator lights up to indicate tem perature warning PROTECTION indica tor lights The heat sink temperature has exceeded 90 C 194 F Check the amplifier ventilation condi...

Page 13: ...390 W 4 STEREO 590 W 590 W 590 W 590 W 590 W 590 W 8 BRIDGED 1180 W 1180 W 1180 W 20 20 kHz THD N 0 1 8 STEREO 350 W 350 W 350 W 350 W 350 W 350 W 4 STEREO 450 W 450 W 435 W 435 W 450 W 450 W 8 BRIDGE...

Page 14: ...26 dB position 13 7 dBu 120V 240V 13 6 dBu 230V 12 2 dBu 10 7 dBu 9 2 dBu 5 2 dBu 32 dB position 7 7 dBu 120V 240V 7 6 dBu 230V 6 2 dBu 4 7 dBu 3 2 dBu 0 8 dBu Maximum Input Voltage MIN 22 dBu Input...

Page 15: ...to GND 4 REMOTE CONTROL NC 5 NC 6 MUTE CH B MUTE On Control Connect the pin to GND max 1mA flows MUTE Off Control Open the pin 5V applied 7 MUTE CH A 8 MONITOR NC 9 NC 10 PROTECTION MUTE STATUS CH B P...

Page 16: ...CTION SIGNAL CLIP LIMIT RE GR GR RE RE BSIG TEMPERATURE SENSOR TEMPERATURE SENSOR PROTECTION CIRCUIT FAN CONTROL CIRCUIT POWER ON DETECT CIRCUIT LIMITER LIMITER PA 5V 5 B 15 15 B 24 24 15V 15V 15V U A...

Page 17: ...CIRCUIT CH B TEMP PROTECTION SIGNAL CLIP LIMIT RE GR GR RE RE SP RELAY BSIG TEMPERATURE SENSOR LED DRIVE CIRCUIT FAN CONTROL CIRCUIT PROTECTION CIRCUIT LIMITER LIMITER PA 24 24 B B 15 15 15V Thermal...

Page 18: ...0V 230 240V In Out Dissipated Btu h kcal h standby 0 08 0 04 5 0 5 17 4 idle 1 0 0 5 35 0 35 119 30 1 8 power 8 ch 4 0 2 2 277 131 146 499 126 4 ch 6 2 3 4 436 188 249 848 214 1 3 power 8 ch 9 3 5 1 6...

Page 19: ...XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual 19 Memo...

Page 20: ...20 XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual Memo...

Page 21: ......

Page 22: ...S G Pro Audio Division 2005 Yamaha Corporation 305POAPx x 01E0 Printed in Vietnam WF37200 Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manua...

Reviews: