4-2
E
1. Put the watercraft on land in a horizontal
position.
2. Insert the garden hose adapter
2
into
the flush hose connector
1
.
3. Connect the garden hose adapter to a
water tap using a hose.
4. Start the engine, and then immediately
turn the water supply on until water flows
continually from the cooling water pilot
outlet.
5. Run the engine at idling speed for about
3 minutes watching the engine condition.
If the engine stops while flushing, turn
the water supply off immediately and
repeat the above steps.
6. Turn the water supply off, and then force
the remaining water out of the cooling
water passages by alternately squeezing
and releasing the throttle lever for 10 to
15 seconds.
7. Stop the engine.
8. Remove the garden hose adapter.
NOTE:
If you use the flushing attachment
4
in the
tool kit, remove the plug
3
and install the
attachment.
Then, follow steps 3 to 8 above.
E_GM6-4.fm Page 2 Tuesday, July 11, 2000 11:28 AM
Summary of Contents for WaveRunner SuperJet 700 2001
Page 2: ......
Page 4: ...E_GM6_info fm Page 2 Tuesday July 11 2000 10 48 AM ...
Page 6: ...E_GM6_info fm Page 4 Tuesday July 11 2000 10 48 AM ...
Page 11: ...1 4 E Warning labels 1 2 3 4 E_GM6 1 fm Page 4 Tuesday July 11 2000 10 49 AM ...
Page 12: ...1 5 E 5 6 7 9 8 E_GM6 1 fm Page 5 Tuesday July 11 2000 10 49 AM ...
Page 13: ...1 6 E 0 A B C E_GM6 1 fm Page 6 Tuesday July 11 2000 10 49 AM ...
Page 14: ...1 7 E Caution label Other labels D E F G H E_GM6 1 fm Page 7 Tuesday July 11 2000 10 49 AM ...
Page 22: ...E MEMO E_GM6 1 fm Page 15 Tuesday July 11 2000 10 49 AM ...
Page 34: ...E MEMO E_GM6 2 fm Page 11 Tuesday July 11 2000 10 51 AM ...
Page 101: ...E 6 EJU00608 APPENDIX Index 6 1 E_GM6 6TOC fm Page 1 Tuesday July 11 2000 11 29 AM ...
Page 104: ...E_GM6 75IX fm Page 3 Tuesday July 11 2000 11 30 AM ...
Page 105: ...shiro fm Page 1 Tuesday August 1 2000 11 12 AM ...