2
Installation and wiring
2-4
2. Installation conditions
This section explains the installation conditions necessary to operate the controller in safe and correct
manner.
Installation location
n
Install the controller inside the control panel.
Installation direction
n
Install the controller on a vertical wall.
Surrounding space
n
Install the controller in a well ventilated location, with space on all sides of the controller (See the figure below.).
20mm
or more
20mm
or more
10mm
or more
10mm
or more
Surrounding space
20mm
or more
20mm
or more
20mm
or more
20mm
or more
TS-S, TS-S2, TS-SH
TS-X, TS-P
23202-M0-00
Ambient operating temperature and humidity
n
The controller's ambient operating temperature and humidity must be maintained within the following ranges.
• Ambient temperature : 0 to 40˚C
• Ambient humidity
: 35 to 85% RH
(no condensation)
Environments to be avoided
n
To ensure safe and correct controller operation, avoid using the controller in the following environments.
• Environments which contain corrosive gases such as sulfuric acid or hydrochloric acid, or where flammable gases and
liquids are present in the atmosphere.
• Environments with excessive dust.
• Environments which contain metal cutting chips, oil, and water, etc., from other machinery.
• Environments subject to excessive vibration.
• Environments where electromagnetic noise or electrostatic noise is generated.
• Environments exposed to direct sunlight.
c
CAutIoN
• Do not install the controller upside down or at an angle. Doing so could reduce the cooling capacity and
cause performance deterioration or malfunctions.
• Provide the prescribed spacing between the controller and the inner face of the control panel, and between
the controller and other devices.
• Avoid using the controller in environments other than those specified. Usage in inappropriate environments
could cause product deterioration and malfunctions.