3 - 66
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
NO
YES
Is the amperage higher
than the standard charging
amperage written on the
battery?
Charge the battery until the charging
voltage reaches 15 V.
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
NOTE:
Set the charging time to a maxi-
mum of 20 hours.
NOTE:
Constant amperage chargers
are not suitable for charging MF
batteries.
CAUTION:
Charger
Ammeter
Voltmeter
Summary of Contents for tmax XP500A
Page 1: ...2005 XP500 XP500A5VU5 AE1 SERVICE MANUAL ...
Page 2: ......
Page 8: ......
Page 9: ...GEN INFO 1 ...
Page 11: ...GEN INFO ...
Page 38: ...SPEC 2 ...
Page 40: ...SPEC ...
Page 68: ...2 28 SPEC OIL FLOW DIAGRAMS 1 Oil strainer 2 Crankshaft ...
Page 69: ...2 29 SPEC OIL FLOW DIAGRAMS 1 Clutch 2 Right main journal bearing 3 Main gallery plug ...
Page 118: ......
Page 119: ...CHK ADJ 3 ...
Page 193: ......
Page 194: ...CHAS 4 ...
Page 198: ...CHAS ...
Page 292: ...4 94 CHAS ANTI LOCK BRAKE SYSTEM XP500A ...
Page 326: ......
Page 327: ...ENG 5 ...
Page 331: ...ENG ...
Page 424: ...COOL 6 ...
Page 426: ...COOL ...
Page 442: ......
Page 443: ...FI 7 ...
Page 445: ...FI ...
Page 476: ...ELEC 8 ...
Page 544: ......
Page 545: ...TRBL SHTG 9 ...
Page 553: ......
Page 556: ......
Page 557: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN ...