ELECTRICAL COMPONENTS
8-102
TIP
Voltage should be measured 30 minutes after
the engine is stopped.
b. Connect a charger and ammeter to the bat-
tery and start charging.
TIP
Set the charging voltage to 16–17 V. If the set-
ting is lower, charging will be insufficient. If too
high, the battery will be overcharged.
c. Make sure that the current is higher than the
standard charging current written on the bat-
tery.
TIP
If the current is lower than the standard charging
current written on the battery, set the charging
voltage adjusting dial to 20–24 V and monitor
the amperage for 3–5 minutes to check the bat-
tery.
d. Adjust the voltage so that the current is at the
standard charging level.
e. Set the time according to the charging time
suitable for the open-circuit voltage.
f. If charging requires more than 5 hours, it is
advisable to check the charging current after
a lapse of 5 hours. If there is any change in
the amperage, readjust the voltage to obtain
the standard charging current.
g. Measure the battery open-circuit voltage after
leaving the battery unused for more than 30
minutes.
▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲▲▲
▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼▼▼
Charging method using a constant volt-
age charger
a. Measure the open-circuit voltage prior to
charging.
TIP
Voltage should be measured 30 minutes after
the engine is stopped.
b. Connect a charger and ammeter to the bat-
tery and start charging.
c. Make sure that the current is higher than the
standard charging current written on the bat-
tery.
TIP
If the current is lower than the standard charging
current written on the battery, this type of battery
charger cannot charge the VRLA (Valve Regu-
lated Lead Acid) battery. A variable voltage
charger is recommended.
d. Charge the battery until the battery’s charg-
ing voltage is 15 V.
TIP
Set the charging time to 20 hours (maximum).
e. Measure the battery open-circuit voltage after
leaving the battery unused for more than 30
minutes.
▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲▲▲
6. Install:
• Battery
7. Connect:
• Battery leads
(to the battery terminals)
TIP
Route the positive battery lead under the nega-
tive battery lead, making sure not to route it on
top of the relay unit.
NOTICE
ECA3D81023
First, connect the positive battery lead “1”,
then the negative battery lead “2”.
8. Check:
• Battery terminals
Dirt
→
Clean with a wire brush.
Loose connection
→
Connect properly.
9. Lubricate:
• Battery terminals
• Standard charging current is reached
Battery is good.
• Standard charging current is not reached
Replace the battery.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
2
2
1
1
Summary of Contents for Star XVS13AA(C) 2011
Page 1: ...2011 SERVICE MANUAL XVS13AA C XVS13CTA C XVS13CA C LIT 11616 24 48 3D8 28197 13 ...
Page 6: ......
Page 8: ......
Page 59: ...TIGHTENING TORQUES 2 32 2 1 ...
Page 63: ...LUBRICATION POINTS AND LUBRICANT TYPES 2 36 ...
Page 66: ...LUBRICATION SYSTEM CHART AND DIAGRAMS 2 39 EAS20410 LUBRICATION DIAGRAMS A A 1 2 2 3 A A ...
Page 68: ...LUBRICATION SYSTEM CHART AND DIAGRAMS 2 41 1 2 ...
Page 69: ...LUBRICATION SYSTEM CHART AND DIAGRAMS 2 42 1 Camshaft 2 Crankshaft ...
Page 70: ...LUBRICATION SYSTEM CHART AND DIAGRAMS 2 43 1 2 ...
Page 71: ...LUBRICATION SYSTEM CHART AND DIAGRAMS 2 44 1 Oil delivery pipe 1 2 Timing chain tensioner ...
Page 72: ...LUBRICATION SYSTEM CHART AND DIAGRAMS 2 45 1 2 3 4 5 6 ...
Page 74: ...COOLING SYSTEM DIAGRAMS 2 47 EAS20420 COOLING SYSTEM DIAGRAMS A A A A 2 1 4 3 5 6 ...
Page 76: ...COOLING SYSTEM DIAGRAMS 2 49 A B B A 4 3 3 1 2 2 A A B B ...
Page 100: ...CABLE ROUTING for XVS13AA C XVS13CTA C 2 73 A D B C 1 2 3 4 5 6 7 8 9 A B 10 11 12 13 14 A B ...
Page 122: ...CABLE ROUTING for XVS13CA C 2 95 C B C B A B A A C B E D 5 6 1 2 3 4 1 2 3 7 5 6 C C ...
Page 126: ...CABLE ROUTING for XVS13CA C 2 99 E A B C D C C A B A B C C 1 1 5 3 2 4 ...
Page 128: ...CABLE ROUTING for XVS13CA C 2 101 A H G B C D E F 2 J I 1 5 2 3 4 A A 7 6 ...
Page 134: ...CABLE ROUTING for XVS13CA C 2 107 ...
Page 137: ......
Page 175: ......
Page 374: ...TRANSMISSION 5 95 ...
Page 388: ...WATER PUMP 6 13 ...
Page 407: ......
Page 415: ...IGNITION SYSTEM 8 8 ...
Page 425: ...CHARGING SYSTEM 8 18 1 AC magneto 2 Rectifier regulator 3 Main fuse 6 Battery ...
Page 427: ...CHARGING SYSTEM 8 20 ...
Page 445: ...SIGNALING SYSTEM 8 38 ...
Page 489: ...FUEL INJECTION SYSTEM 8 82 ...
Page 496: ...ELECTRICAL COMPONENTS 8 89 EAS27970 ELECTRICAL COMPONENTS 1 5 4 6 7 9 8 10 11 12 13 15 2 3 14 ...
Page 498: ...ELECTRICAL COMPONENTS 8 91 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...
Page 530: ......
Page 531: ......
Page 532: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN ...