- 8 -
[Regulating rod check / adjustment]
①
Pull the Silent lever to activate the Silent mechanism.
②
Check and adjust the contact angle of regulating rod.
③
Disengage Silent mechanism and make sure that the regulating rod does not
contact the jack.
◆
Adjustment of contact angle to regulating rod
Angle position Regulating rod (b) and small jack’s knob (a) respectively contact in the
center position (Fig.12).
Adjustment
spot
Regulating rod drive lever adjustment screw installed in the back of the
action treble side (Fig.13: Rotation end position changes.)
Fig.12
Fig.13
・
To rotate regulating rod more : Adjust screw clockwise
・
To rotate regulating rod less : Adjust screw counterclockwise