7. Maintenance and Test Modes 

 

■Maintenance mode (measurement mode) 

 

Maintenance mode is a program to adjust the key sensor and damper pedal sensor 
detection positions by measurement. 
Measurement by maintenance mode shall be required in the following cases; 

If the detection position is out of standard, when checked in the test mode. 

When replacing the key sensor rail, damper pedal sensor and DM sheet, etc.   

                                   

 

[Key sensor measurement] 

For key sensor measurement, there are “All-key measurement” to rewrite the 

measurement of all keys and “1-key measurement” to rewrite only a designated key. 

 

 
Key sensor measurement “All-key measurement” / “1-key measurement” procedure 

No.  Measurement item 

All-key measurement

   

1-key measurement

   

 

 
 

Start-up 

10F#+12G#+14A#+ power 
ON (release keys in 2 sec.) 

 

A tone will be sounded at 

regular 2 sec intervals. 
(Waiting mode) 
→    Wait for about 30sec. 

9F+11G+ power ON (release 

keys 2 sec.) 

 

Two successive tones 

will be sounded at regular 1 
sec intervals. (Key selection 
status) *1 

 

Start of rest value 

measurement 

Depress the damper pedal. 

 

Two successive tones 

will be sounded at regular 1 
sec intervals. 

Press 1 key to be measured. 

 

The tone will change to 

the tone of the key to be 
measured. *2 

Rest value 

measurement 

Confirm that key is in the rest 
position. 

Confirm that key is in the rest 
position. 

 

Rest value registration 

Depress the damper pedal. 

 

Three successive tones 

will be sounded at regular 1 
sec intervals. 

Depress the damper pedal. 

 

Three successive tones 

will be sounded at regular 1 
sec intervals. 

End value 

measurement 

Press 1 to 88 keys lightly one 
by one to the end position. 

Press 1 to 88 keys lightly one 
by one to the end position. 

 

End value registration 

Depress the damper pedal. 

 

A tone will be sounded at 

regular 2 sec intervals. 

Depress the damper pedal. 

 

A tone will be sounded at 

regular 2 sec intervals. 

 

Flash RAM writing 

Depress the soft pedal. 

 

The writing will be 

completed in about 10 sec, 
then 76C will sound 3 times. 

Depress the soft pedal. 

 

The writing will be 

completed in about 10 sec, 
then 76C will sound 3 times. 

 

Complete 

Power OFF 

Power OFF 

Note 1: If the tone is consonant (“do”, “mi”, “sol” and “do”), the writing has already been done in the table.   
If the tone is dissonant, the writing has not been done in the table. 
Note 2: One key measurement requires the same procedure as for the measurement of all keys. 
If more than one key is to be measured, repeat the steps 3 through 6 and then proceed to step 7). 

Summary of Contents for Silent Piano GB1KS

Page 1: ...MAINTENANCE HANDBOOK GB1KS MHB29 May 2011 ...

Page 2: ...n see GPS GB1 Service manual PP008615 Table of Contents 1 Unit structure and Names 2 2 Adjustment Checking points 4 3 Piano regulation caution 5 4 Check regulation and Adjustment Silent mechanism 6 5 Silent let off Adjustment 9 6 Sensor Unit Adjustment 12 7 Maintenance and Test Modes 13 8 Unit Connection Diagram 16 9 Parts List 17 ...

Page 3: ...operation lever and detects key and pedal movement Key Sensor Unit Key sensor unit adjustment P 12 Key sensor measurement P 13 Regulating Rod Check adjustment P 8 Silent let off adjustment P 9 11 Hammer Shank Stopper Check adjustment P 6 7 Switch Box Front side Power Switch Reverb Adjustment Knob Right side diagram Volume Knob Headphone Jacks Test Switch Back side Pedal Connector Key Connector DC ...

Page 4: ...ensor ON OFF How to check adjust the sensor detection position P 14 Damper Pedal Sensor Variable Resister VR Sensor ON Half OFF Damper pedal sensor measurement P 14 How to check the sensor detection position P 14 Damper pedal sensor position adjustment P 15 Bottom face diagram Switch Box ...

Page 5: ... 8 Silent let off adjustment Level adjustment of the regulating rod Escapes at the shank stopping position 1 to 2mm before shank stopping position P 9 Sensor unit adjustment Key sensor unit adjustment Gap between the bottom surface of black keys and the upper surface of key sensor unit when pressing the black keys to the lowest position 3 8 to 4 0mm P 12 Adjustment of pedal sensor unit P 12 15 Mai...

Page 6: ...n for tuning and voiving operate the Silent lever to release the Silent mechanism Fig 5 and remove the key sensor connector in front of the action Fig 6 Fig 5 Fig 6 Hammer let off approx 2mm normally same distance as GP Hammer drop 2 point matching Fig 7 simultaneous contact of and Other regulation same as GP Fig 7 ...

Page 7: ...nt In the Silent mode the sostenuto pedal is ineffective Hammer shank stopper check adjustment Pull the Silent lever to activate the Silent mechanism Adjust and set the hammer shank stopper cushion to contact the hammer shank vertically Visual confirmation is possible Fig 8 Set the hammer shank stopping position to 5 6mm from the strings Fig 11 Disengage the Silent lever and make sure that the ham...

Page 8: ...r cushioning Thickness t Component No Remarks 5 5mm T6210100 Used in product 5 0mm T6210110 Same as above 4 5mm T6210120 Same as above 4 0mm T6210130 Same as above 3 5mm T6210140 Same as above 3 0mm T6210150 For adjustment 2 5mm T6210160 Same as above Cushion length are all 378mm Cut as follows Bass 365mm Middle 375mm Treble 232mm Shank stopping position 5 6mm from the string Thickness t Cushionin...

Page 9: ... jack Adjustment of contact angle to regulating rod Angle position Regulating rod b and small jack s knob a respectively contact in the center position Fig 12 Adjustment spot Regulating rod drive lever adjustment screw installed in the back of the action treble side Fig 13 Rotation end position changes Fig 12 Fig 13 To rotate regulating rod more Adjust screw clockwise To rotate regulating rod less...

Page 10: ...es at the shank stopping position 1 to 2mm 6 to 8mm from the string At this time jack A and a contact B and b almost simultaneously Adjustment spot Regulating rod adjustment screw Fig 16 Adjustment hint For 1 screw rotation Silent let off changes 3mm Adjustment method P 10 11 In Silent mode let off jack escapement drop cannot be seen To confirm Silent let off increase drop to 8 to 9mm Adjust Silen...

Page 11: ...ulating rod position With the Silent mechanism ON check Silent mode let off at the both ends of each section Silent mode let off measurement 1 to 2mm from the hammer shank stopping position and normally 6 to 8mm from the string Disengage Silent mechanism and remove connector in front of the action and remove the connector in front of the action Then pull out the action and increase the hammer drop...

Page 12: ...obs are contacting the regulating button and regulating rod almost simultaneously If this simultaneous contact is drastically different check the following parts Hammer shank stopping position P 7 Normal hammer let off measurement P 5 Silent mode let off measurement P 9 If the small jack s knob A and regulating button contact is earlier in the Silent mode there will be a negative effect with the t...

Page 13: ...ets 4 Adjustment screws 2 each Adjust from the bottom of the keyboard with 2 adjustment screws to make a gap of appropriate size Make sure the gap between the keyboard and Key sensor rail is parallel Pedal sensor unit adjustment Damper pedal detection position adjustment shall be done in the maintenance mode by confirming the buzzer sounds See the maintenance mode P 13 14 Shift pedal sensor detect...

Page 14: ...y to be measured The tone will change to the tone of the key to be measured 2 3 Rest value measurement Confirm that key is in the rest position Confirm that key is in the rest position 4 Rest value registration Depress the damper pedal Three successive tones will be sounded at regular 1 sec intervals Depress the damper pedal Three successive tones will be sounded at regular 1 sec intervals 5 End v...

Page 15: ...heck status 4 1 A buzzer continuous tone is sounded 2 A buzzer intermittent tone is sounded 3 A buzzer quick intermittent tone is sounded 4 When the writing is finished the tone 76C will be sounded every second If the writing is not finished successfully the tone 78D and the tone 76C will be sounded alternately Test mode How to start up the test mode Turn on the power switch while pressing the low...

Page 16: ...al at stroke end Quick intermittent tone 3 Set the buzzer to sound of 4 when the shift pedal moves the action to the right by 1mm Damper Shift pedal sensor adjustment spots Fig 19 SW Box Test Test start up termination Connect headphones and turn on the power Push test switch SW on the backside of the switch box to start the test press SW again to terminate Fig 20 Damper Pedal Sensor Adjustment Scr...

Page 17: ...hord sound AD test Detects reverb knob rotation and damper pedal depth and then produces a chromatic scale During the test Rotating the reverb knob clockwise produces a chromatic scale from low to high counter clockwise rotation produces a chromatic scale from high to low Pressing the damper pedal produces a chromatic scale from low to high releasing the pedal produces the scale from high to low C...

Page 18: ...87500 6 ROTARY VARUABLE RESISTOR HS41252R FOR DAMPER PEDAL SENSOR 7 PEDAL UNIT SG WR310300 SHIFT PEDAL SENSOR UNIT 8 SG CONNECTOR ASSEMBLY WR687400 9 LEAF SWITCH WM242100 FOR SHIFTPEDAL SENSOR 10 SWITCH BOX UNIT WS184500 11 DM CIRCUIT BOARD WS184600 12 AM CIRCUIT BOARD WH126000 13 DC IN CIRCUIT BOARD WH126100 14 HEADPHONES VQ78520 HPE 170 15 AC ADAPTOR WK014700 PA 150U 16 HEADPHONE HANGER WH125500...

Reviews: