Charging the Battery Pod
To Remove the 275L Nose Cone and charge the Battery
Pod, User MUST follow these instructions to avoid any
injury.
1. ALWAYS ensure that the Master Switch is in OFF position.
2. ALWAYS ensure that the 275L is out of the water, dry and
placed in a dry area.
3. Pull the four Latches down and remove the nose cone by
using the left and right Latches to break the seal if
necessary (see Fig. 11 and Fig. 12) and jump to Step 9.
4. If the nose-cone cannot be opened by pressing the
latches, replace the Retractable rubber handle on the
SEASCOOTER™ 275L. (see Fig. 13)
5. Release the Vent plug on top of the Nose Cone.
17
16
Fig.16
Charging Base
Battery Pod
Charging
Indicator
Warning!
Replace the battery immediately if it is damaged.
Rubber
Ring
Retractable rubber handle
Latch
Hinge
Left and
right Latches
Top and
Bottom
(on Back)
Latches
Press
inward
to open
Inner
Latches up
Fig.12
Fig.11
Fig.13
6. Pull the rubber ring through the retractable rubber handle
and attach both ends around the top and bottom latch
hinge as shown in Fig. 13.
7. Screw the pump nozzle to the vent chamber and pump air
in until the Nose Cone pops off
(see Fig. 14).
IMPORTANT
: ALWAYS attach the Rubber Ring before
using the pump. The Nose Cone can pop off and cause
injury if the Rubber Ring is not attached and tighly
secured.
8. Remove the Rubber Ring and remove the Nose Cone
(see Fig. 15).
9. Allow two minutes for any gases to dissipate.
10. Take out the Battery Pod from the unit.
11. Connect the Battery Pod to the Charging Base.
(see Fig. 16)
12. Plug the Charging Base into the mains, and turn on the
supply.
13. Charging will take around 12-14 hours for a fully
discharged battery. When the Battery Pod is charging, the
RED LED light on the Battery Pod remains flashing.
When the battery is fully charged, the GREEN LED
flashes. (see Fig. 16)
Fig.14
Fig.15
14. Unplug the Charging Base from the electrical socket/plug.
15. Allow battery to stand for 30 minutes before using it.
16. Unplug the Battery Pod from the Charging Base.
17. When ready to use, reconnect to the unit in the correct
position. (see Fig. 17)
18. MAKE SURE the O-ring Seals and sealing surfaces are
clean and fully lubricated
with the supplied grease
EVERYTIME (you can also
buy this at your local
hardware store) before
replacing the Nose Cone.
(see Fig. 18)
19. Ensure the Vent O Ring is
fitted correctly into the
groove and fully lubricated
with the supplied grease. (see
Fig. 18)
20. MAKE SURE to screw in the
Vent Plug to seal the vent.
21. Replace the Nose Cone and
close the Latches.