Cause:
The temperature of the heatsink is excessive.
Supplementary information:
The protection function
worked due to the temperature limit being exceeded.
Causes could be poor ventilation or a defect related to
the thermal sensor.
Turning on the power without correcting the abnormality
will cause the protection function to work in 1 seconds
and the power supply will be shut off.
2-4. When the protection function worked due to
excessive heatsink temperature.
●
History of protection function
When the protection function has worked, its history
is stored in memory with a backup.
Even if no abnormality is noted while servicing the
unit, an abnormality which has occurred previously
can be defined as long as the backup data has been
stored.
For details, refer to “P2 PROTECTION HISTORY”
menu.
T M P 1 P R T : x x x L
2-4. ヒートシンクの異常温度によりプロテクション
が働いた場合
AD conversion value when the protection function is working
プロテクションが働いたときの電圧の A/D 変換値
原因:
ヒートシンクの温度が異常。
補足:
温度制限を越えた原因で、プロテクションが働い
たことを示します。
異常状態のまま電源を入れると、1 秒後にプロテクション
が働き、電源が切れます。
● プロテクションの履歴
プロテクションが働いた場合、その履歴をバックアッ
プして記憶しています。
修理のときに異常が認められなくても、バックアッ
プが残っていれば、お客様のところで起きた異常を
区別できます。
詳細は、“P2 PROTECTION HISTORY” メニューを参照
してください。
27
RX-V771
RX-V771
Summary of Contents for RX-V771
Page 4: ...K model A model T model 4 RX V771 RX V771 ...
Page 5: ...B G F models L H models J model H model 5 RX V771 RX V771 ...
Page 6: ... REMOTE CONTROL PANELS RAV442 R A L H J models RAV443 T K B G F models 6 RX V771 RX V771 ...
Page 99: ...MAIN 2 Side B MAIN 6 Side B A B C D E F G H I J 1 2 3 4 5 6 7 RX V771 99 ...
Page 145: ... CONFIGURING THE SYSTEM SETTINGS RX V771 147 ...
Page 146: ... システム設定を変更する RX V771 148 ...
Page 147: ...MEMO 149 RX V771 RX V771 149 ...
Page 148: ...RX V771 ...