Cause:
An excessive current flowed through the power
amplifier.
Supplementary information:
As over current of the
power amplifier is detected, check condition of each
power transistor.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
2. When the protection function worked to turn
off the power:
The data of protection function which worked at the
moment is displayed. Then “A1-1. DSP MARGIN” menu
is displayed in a few seconds.
Note: At that time if you reactivate the self-diagnostic
function after turning off the power once
by pressing the “MAIN ZONE ” key, “NO
PROTECT” will be displayed because that
situation is equal to “1. When the power is
turned off by usual operation:” described above.
However the protection function history is stored
in a back-up IC with a backup. For details, refer
to “P2 PROTECTION HISTORY” menu.
2-1. When there is a history of protection function
due to excess current.
I P R O T E C T
2. プロテクションが働いて電源が切れた場合:
そのときに働いたプロテクションの情報が表示され
ます。数秒後、“A1-1 DSP MARGIN” メニューが表示
されます。
注) このときに “MAIN ZONE ” キーを押していっ
たん電源を切った後にダイアグを再起動する
と、前述の「1. 通常の操作で電源を切った場合」
に相当するので、“NO PROTECT” が表示されま
す。
ただし、プロテクションの履歴はメモリーに
バックアップして記憶されます。詳細は、“P2
PROTECTION HISTORY” メニューを参照してく
ださい。
2-1. 過電流によるプロテクション履歴がある場合
原因:
パワーアンプに過電流が流れた。
補足:
パワーアンプの過電流を検出していますので、各
パワートランジスタの状態を確認してください。
異常状態のまま電源を入れると、瞬時にプロテクション
が働き、すぐに電源が切れます。
Notes)
• Applying the power to this unit without correcting
the abnormality can be dangerous and cause
additional circuit damage. To avoid this, if “I
PROTECT” protection function works 1 time,
the power will not turn on even when the “MAIN
ZONE ” key is pressed. In order to turn on the
power again, start up the self-diagnostic function.
• The output transistors in each amplifier channel
should be checked for damage before applying
power to this unit.
•
Amplifier current should be monitored by
measuring DC voltage across the emitter resistors
for each channel.
注意!
・ 異常状態のまま本機の電源を入れると、危険な状態
になり、さらに回路が損傷を受ける原因になります。
それを避けるために、「I PROTECT」が1回働いた場
合、それ以降 “MAIN ZONE ” キーを押しても電源
が入らなくなります。再度電源を入れる場合、ダイ
アグを起動してください。
・ 本機の電源をいれる前に、各パワーアンプの出力ト
ランジスタに損傷がないかチェックしてください。
・ パワーアンプの電流は、各チャンネルのエミッター
の抵抗器間 DC 電圧を測定することによりモニター
してください。
25
RX-V771
RX-V771
Summary of Contents for RX-V771
Page 4: ...K model A model T model 4 RX V771 RX V771 ...
Page 5: ...B G F models L H models J model H model 5 RX V771 RX V771 ...
Page 6: ... REMOTE CONTROL PANELS RAV442 R A L H J models RAV443 T K B G F models 6 RX V771 RX V771 ...
Page 99: ...MAIN 2 Side B MAIN 6 Side B A B C D E F G H I J 1 2 3 4 5 6 7 RX V771 99 ...
Page 145: ... CONFIGURING THE SYSTEM SETTINGS RX V771 147 ...
Page 146: ... システム設定を変更する RX V771 148 ...
Page 147: ...MEMO 149 RX V771 RX V771 149 ...
Page 148: ...RX V771 ...