P2. PROTECTION HISTORY
This menu is used to display the history of protection function.
All history of protection function will be erased by pressing the “STRAIGHT” key.
*
Numeric values in the figure are given as reference only.
S1. FIRMWARE UPDATE
Not for service.
S 1 - 1
F / W U P D A T E ?
P2-1. History 1
H: Displayed when the voltage is HIGHER than upper limit.
L: Displayed when the voltage is LOWER than lower limit.
xxx: A/D conversion value of voltage at the moment when the protection function
worked.
(Reference voltage: 3.3 V=255)
P2-2. History 2
P2-3. History 3
P2-4. History 4
P 2 - 1
1 s t : P S 2 0 0 0 L
P 2 - 2
2 n d : T M P 1 0 0 0 L
P 2 - 3
3 r d : D C 0 0 0 L
P 2 - 4
N o P r t
67
RX-V675/HTR-6066/RX-A730/TSR-6750
RX-V675/HTR-6066/
RX-A730/TSR-6750
Summary of Contents for RX-V675
Page 126: ...MEMO MEMO RX V675 HTR 6066 RX A730 TSR 6750 126...
Page 167: ...167 RX V675 HTR 6066 RX A730 TSR 6750 RX V675 HTR 6066 RX A730 TSR 6750 ADVANCED SETUP...
Page 168: ...168 RX V675 HTR 6066 RX A730 TSR 6750 RX V675 HTR 6066 RX A730 TSR 6750...
Page 181: ...181 RX V675 HTR 6066 RX A730 TSR 6750 RX V675 HTR 6066 RX A730 TSR 6750 MEMO...
Page 182: ...RX V675 HTR 6066 RX A730 TSR 6750...