●
Canceling Self-Diagnostic Function
1. Before canceling self-diagnostic function, execute setting for “S3. FACTORY PRESET” menu. (Memory initialization
inhibited or Memory initialized).
*
In order to keep the user memory preserved, be sure to select PRESET INHIBIT (Memory initialization inhibited).
2. Press the “MAIN ZONE ” key to turn off the power.
N O P R O T E C T
A 1 - 1
D S P M A R G I N
Main menu display
Opening message
After a few seconds
●
Display provided when Self-Diagnostic Function started
The display is as described below depending on the situation when the power to this unit is turned off.
1. When the power is turned off by usual operation:
“NO PROTECT” is displayed. Then “A1-1. DSP MARGIN” is displayed in a few seconds.
Cause:
An excessive current flowed through the power amplifier.
Supplementary information:
As over current of the power amplifier is detected, check condition of each power transistor.
Turning on the power without correcting the abnormality will cause the protection function to work immediately and the
power supply will instantly be shut off.
2. When the protection function worked to turn off the power:
The information of protection function which worked at that time is displayed. Then “A1-1. DSP MARGIN” is displayed in
a few seconds.
Note: At that time if you restart the self-diagnostic function after turning off the power once, “NO PROTECT” will be
displayed. That is because that situation is equal to “1. When the power is turned off by usual operation:”.
However history of the protection function is stored in memory as backup data. For details, refer to “P2.
PROTECTION HISTORY” menu.
2-1. When there is a history of protection function due to excess current.
I P R O T E C T
Notes:
•
Applying the power to this unit without correcting the abnormality can be dangerous and cause additional
circuit damage. To avoid this, if “I PROTECT” protection function works 1 time, the power will not turn on even
when the “MAIN ZONE ” key is pressed. In order to turn on the power again, start up the self-diagnostic
function.
•
The output transistors in each amplifier channel should be checked for damage before applying power to this
unit.
•
Amplifier current should be monitored by measuring DC voltage across the emitter resistors for each channel.
33
RX-V675/HTR-6066/RX-A730/TSR-6750
RX-V675/HTR-6066/
RX-A730/TSR-6750
Summary of Contents for RX-V675
Page 126: ...MEMO MEMO RX V675 HTR 6066 RX A730 TSR 6750 126...
Page 167: ...167 RX V675 HTR 6066 RX A730 TSR 6750 RX V675 HTR 6066 RX A730 TSR 6750 ADVANCED SETUP...
Page 168: ...168 RX V675 HTR 6066 RX A730 TSR 6750 RX V675 HTR 6066 RX A730 TSR 6750...
Page 181: ...181 RX V675 HTR 6066 RX A730 TSR 6750 RX V675 HTR 6066 RX A730 TSR 6750 MEMO...
Page 182: ...RX V675 HTR 6066 RX A730 TSR 6750...