48
RX-V2065/HTR-6295
RX-V2065/HTR-6295
DC/TH
DC:
Power amplifier DC (DC voltage) output is detected.
Normal value:
32 to 74
(Reference voltage: 3.3 V=255)
TH:
Temperature on the heatsink is detected.
Normal value:
0 to 124
(Reference voltage: 3.3 V=255)
*
If DC or TH becomes out of the normal value range, the protection function works to turn off the power.
D C : 0 4 9 T H : 1 1 7
During normal operation
Value for starting limiter operation
Value for canceling limiter operation
PLDET (8 ohms/6 ohms)
255 / 255
87 / 146
125 / 171
LIM (Limiter control)
H
L
H
During normal operation
Value for starting limiter operation
Value for canceling limiter operation
PLDET (8 ohms/6 ohms)
255 / 255
100 / 100
131 / 131
LIM (Limiter control)
H
L
H
IMP/PL
IMP:
8 or 6 ohms impedance setup detection
IMP 8: 8 ohms setting
IMP 6: 6 ohms setting
PL:
PLDET (Power amplifier output voltage detection)
The power amplifier output voltage is detected and the power amplifier input voltage is controlled according to the
detected output voltage.
(Reference voltage: 3.3 V=255)
I M P : 8 P L : 2 5 5
U, C, T, K, A, B, G, E, F models (Reference voltage: 3.3 V=255)
R, L models (Reference voltage: 3.3 V=255)