RX-V1500/DSP-AX1500
23
RX-V1500/
DSP-AX1500
Cause:
The voltage in the power supply section is
abnormal.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
When there is a history of protection
function due to abnormal voltage in
the power supply section
電源部の電圧異常によるプロテク
ション履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Voltage display in %
電圧の%表示
When there is a history of protection
function due to abnormal DC output
DC出力異常によるプロテクション
履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Cause:
DC output of the power amplifier is abnormal.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 3 seconds later
and the power supply will be shut off.
原因: パワーアンプのDC出力が異常。
補足: 異常時の電圧の状態を、5Vを100%とした値で%表
示します。
異常状態のままパワーオンすると、3秒後にプロテクショ
ンがかかり、電源が切れます。
原因: 電源部の電圧が異常。
補足: 異常時の電圧の状態を、5Vを100%とした値で%表
示します。
異常状態のままパワーオンすると、1秒後にプロテクショ
ンがかかり、電源が切れます。
When there is a history of protection
function due to excessive heat sink
temperature
放熱器の異常温度によるプロテク
ション履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Voltage display in %
電圧の%表示
Cause:
The temperature of the heat sink is excessive.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 500%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
* Additional causes of protection can be due to loose
connections, associated components, CPU, etc.
* For the protection voltage value, refer to DIAG menu
No.12 described later.
原因:放熱器の温度が異常。
補足: 異常時の電圧の状態を、5Vを500%とした値で%表
示します。
異常状態のままパワーオンすると、1秒後にプロテクショ
ンがかかり、電源が切れます。
※ 前記の異常原因の他に、コネクターのはずれやCPU周
辺などに原因がある場合があります。
※ プロテクションの電圧値に関しては、後述のダイアグメ
ニューNo.12を参照してください。