12. AD DATA CHECK / FAN TEST
This menu is used to display the A/D conversion value
of the main CPU which detects panel keys of the main
unit and protection functions in % using the sub-menu.
During signal processing, the condition before
execution is maintained.
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
However, it is possible to advance to the next sub-
menu by turning the VOLUME of the main unit. When
using this function, note that turning the VOLUME more
than 1 click would cause the volume value to change.
* The figures in the diagram are given as reference
only.
DC/PS
(protection detection)
DC: DC detect protection value (Normal value: 1 to 13)
PS: Power supply voltage protection value (Normal value:
19 to 29)
* If DC or PS is out of the normal value range, the
protection function works to turn off the power.
(Reference voltage: 5V=100%)
12. AD DATA CHECK / FAN TEST
本体パネルキー、プロテクションなどを検出しているメ
インCPUのA/D変換の値を、サブメニューで%表示しま
す。信号処理は実行前の状態を維持します。
K0/K1のメニューにすると、全キーの値を検出するため
キー操作はできなくなりますが、本体のVOLUMEを回
すことにより、次のサブメニューに進めることができま
す。このとき1クリック以上回すと、ボリューム値が変
化するので注意してください。
※図中の数値は参考例です。
DC/PS
(プロテクションの検出)
DC:DC検出プロテクションの値(正常値1〜13)
PS:電源電圧プロテクションの値(正常値19〜29)
※ DC、PSは正常値を外れるとプロテクションが働き、電
源オフされます。
(基準電圧:5V=100%)
THM/FAN OUT
(temperature detection/fan drive level)
THM: 500% display of the voltage based on the
temperature detected value.
Reference voltage: 5V=500% (Normal value: 10 to
139)
Fan: Current fan drive level on the left and the past fan
drive history on the right.
THM/FAN OUT
(温度検出/ファン駆動レベル)
THM: 温度検出値で電圧の500%表示、
基準電圧は5V (正常値: 10〜139)
Fan: 左側は現在のファン駆動レベル、右側は過去のファ
ン駆動履歴
REC-OUT
(Select position)
Not applied to this model.
REC-OUT (選択位置表示)
このモデルには適用されません。
Display
H
M
L
fan drive level
HIGH
MID
LOW