RX-E100
RX-E100
7
Preset group
A
B
C
D
E
P1
P2
P3
P4
P5
P6
P7
P8
CAUTION : When executing Test mode No. 2 RAM CLEAR, be sure to write down the preset memory contents of the
tuner, using a table like the one shown below. Execution of RAM CLEAR will set the memory contents of the
tuner back to the factory preset state which means that all the memories preset by the user will be erased.
●
FACTORY PRESET
NOTE 1) PRESET PAGE ................................................. A : FM
B : AM
C : FM
D : AM E : FM
BAND
FM (MHz)
AM (kHz)
MARKETS
U, C, R
(100k/10k)
A, B, G, R,
(50k/9k)
U, C, R
(100k/10k)
A, B, G, R
(50k/9k)
8
107.9
107.90
1440
1440
7
106.1
106.10
1350
1350
6
88.1
88.10
900
900
5
107.9
108.00
1710
1611
4
101.5
101.50
530
531
3
87.5
87.50
1400
1404
2
95.1
95.10
1080
1080
1
98.1
98.10
630
630
PRESET No.
■
AMP ADJUSTMENTS
●
Confirmation of Idling Current
1) No signal applied.
2) Non-loaded condition.
3) Aging is not neccessary.
Note
If the measured voltage exceeds 5mV, cut the lead wire of R197(L ch)
or R204(R ch) and then check again if each measured value satisfies the
rating.
Item
MAIN L
MAIN R
Test Poin
R214
(Between terminal)
R220
(Between terminal)
Rating (DC)
0.1mV—5mV
Note)
•
If R197(L ch) or R204(R ch) have already been cut off and
idling current does not flow, reconnect R197(1k
Ω
) or
R204(1k
Ω
).
•
Q112 and Q115 are transistors for temperature correction.
Apply silicone grease to the contact surface with the heat
sink.
R197 (L ch)
R204 (R ch)
Cut OFF
0.1mV ~ 5mV (DC)
R214 (L ch)
R220 (R ch)
R220
R214
R204
R197
Q115
Q112
* Confirm that the idling current is 0.25mV — 15mV after 60 minutes.