RP-U200
RP-U200
12
9. ERROR
(Error history)
1 – 8 E0 –E7 (Error history)
The history of up to 8 errors is stored in memory. The error
codes are used to display it.
9. CLEAR (Error history clear)
Clears the entire error history in memory and overwrites
with the normal value (00).
10. RETURN
Returns the menu to the main menu (9. ERROR).
Error code
00
11 – 14
21 – 2B
2C – 2E
2F
41 – 46
80
81
82
83
84
85
90
91
92
93
A0
Description
No error
USB internal error
USB interrupt error
USB communication error (*1)
USB interrupt transmission error
USB stream error (*2)
Checksum error
RAM (IC447) Read/Write error
AC3D(IC417) Read/Write error
EGAV (IC475) Read/Write error
Backup RAM initialized at the power ON (*3)
RAM for Y-mersion coefficient initialized at the power ON
Detection of abnormality in power voltage
Detection of current of power amplifier (unused)
Detection of DC of power amplifier (unused)
Detection of abnormality in Tri-path amplifier (unused)
Auto power OFF (24h)
(*1) : When the AC plug is plugged and unplugged with USB
connected, this error may be recorded but it causes no
problem in actual use.
(*2) : This error is not as fatal at to cause any problem in actual
use.
(*3) : This code is recorded in the error history at least once
because the memory is cleared at the time of shipping from
the factory.
10. DIT
(Digital input/output control)
1. GENERAL
GENERAL category code output (0x00)
2. CD
CD category code output (0x01)
3. PCM Enc
PCM Encoder/decoder category code output (0x02)
4. DAT
DAT category code output (0x03)
5. BS JPN
BS JAPAN category code output (0x04)
6. Synthe
Synthesizer category code output (0x05)
7. AD
A/D converter category code output (0x06)
8. SD
Solid state memory category code output (0x08)
9. BS Eur
BS Euro category code output (0x0E)
10. MIXER
Digital signal mixer category code output (0x12)
11. SFC
Sampling rate converter category code output (0x1A)
12. DSP
Digital sound processor category code output (0x2A)
13. L Pa:Ch
Ch Change L bit parent
$^
child
14. DIR RV
Digital interface receive code display
15. RETURN
Returns the menu to the main menu (10. DIT).