36
R-N402/R-N402D
R-N402/R-N402D
P2. PROTECTION HISTORY
T
his menu is used to display the history of protection function.
In the history 1 to
4
, the setting information for operation of each protection function will be stored.
A
ll history of protection function and setting information will be erased by pressing the
“
RETURN
”
key.
*
N
umeric values in the figure are given as reference only.
P2-1. HISTORY 1
H: Displayed when the voltage is
HIGHER than upper limit.
L: Displayed when the voltage is
LOWER than lower limit.
xxx: A/D conversion value of
voltage at the moment when
the protection function worked.
(Reference voltage: 3.3 V=255)
P2-2. POWER PORT 1
Not for service.
P2-3. LAST INPUT 1
The input source which was
selected last is displayed in
hexadecimal notation.
P2-4. LAST VOLUME LEVEL 1
The volume level which was
selected last is displayed.
-80.0 to +16.5 dB
P2-5. HISTORY 2
P2-6. POWER PORT 2
P2-7. LAST INPUT 2
P2-8. LAST VOLUME LEVEL 2
P2-9. HISTORY 3
P2-10. POWER PORT 3
P2-11. LAST INPUT 3
P2-12. LAST VOLUME LEVEL 3
P2-13. HISTORY 4
P2-14. POWER PORT 4
P2-15. LAST INPUT 4
P2-16. LAST VOLUME LEVEL 4
P2-1
1.PS1 000L
P2-5
2.I Prt
P2-2
1.P-PORT:----
P2-3
1.INPUT: 0x09
P2-4
1.VOL.:
P2-7
2.INPUT: 0x0D
P2-6
2.P-PORT:----
P2-8
2.VOL.:
P2-9
3.Dc
P2-10
3.P-PORT:----
P2-11
3.INPUT: 0x05
P2-12
3.VOL.:
P2-13
4.Tmpx
P2-14
4.P-PORT:----
P2-15
4.INPUT: 0x06
P2-16
4.VOL.:
Summary of Contents for R-N402
Page 3: ...3 R N402 R N402D R N402 R N402D FRONT PANELS R N402 R N402D ...
Page 4: ...4 R N402 R N402D R N402 R N402D REAR PANELS R N402 U model R N402 R model R N402 T model ...
Page 5: ...5 R N402 R N402D R N402 R N402D R N402 K model R N402 A model R N402 B G models ...
Page 6: ...6 R N402 R N402D R N402 R N402D R N402 L model R N402 S model R N402D B G models ...
Page 51: ...51 R N402 R N402D J I H G F E D C B A 1 2 3 4 5 6 7 Side B DIGITAL 1 Side B DIGITAL 2 ...
Page 60: ...60 R N402 R N402D MEMO MEMO ...
Page 82: ...83 R N402 R N402D R N402 R N402D MEMO ...
Page 83: ...R N402 R N402D ...