![background image](http://html2.mh-extra.com/html/yamaha/px10/px10_service-manual_3250772052.webp)
52
PX10/PX8/PX5/PX3
2) The index of the rotary potentiometer of both A/B is aligned
with the minimum position as follows.
It will end, if the both SIGNAL LED lights up.
The voltage value for every click saves in the
fl
ash memory.
〈
Service inspection screen
〉
Left end
✽
is a selecting cursor.
The fault location at the time of FAIL
This is not failure. This cause was not successful when you
performed calibration.
It is necessary to retry “5-14-3. Calibration 2”.
5-15 Power off
Contents
Inspect the shutdown of the power supply when
POFF-REQ is activated.
At this time, it also checks that /PWR-OFF occurs
automatically.
Advance preparation
None.
Note
In Final Assy or Service inspection, A power supply is
shut down while the power switch has been an ON state.
You need to turn off a power switch manually, after
ending an inspection visually.
It is set to “FAIL” when there is no response, even if
PWR-OFF becomes temporary standard time.
〈
Service inspection screen
〉
The fault location at the time of FAIL
Around /POFF-REQ, POFF-REQ.