![Yamaha MU10 Owner'S Manual Download Page 32](http://html.mh-extra.com/html/yamaha/mu10/mu10_owners-manual_902730032.webp)
31
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
MIDI Data Format
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
Device Number
01001100
4C
XG Model ID
00000010
02
Address High
00000001
01
Address Mid
00001011
0B
Address Low
01000000
40
Data (MSB)
00000000
00
Data (LSB) Æ fixed at
00.
11110111
F7
End of Exclusive
When this data is received, the MU10 will change
the effect Dry/Wet balance of Stage 1 to 50%
each.
Be sure to allow enough time for the procedure to
take place by inserting an empty measure at the
top of the song for every channel.
2.1.4.3 Multi Effect1 Data parameter change
See Tables 1-1 and 1-3.
2.1.4.4 Multi Part Data parameter change
See Tables 1-1 and 1-4.
2.1.4.5 A/D Part Data parameter change
See Tables 1-1 and 1-5.
2.1.4.6 Drums Setup Data parameter change
See Tables 1-1 and 1-6.
If a Drum Setup Reset parameter change message
(Table 1-2) is received, the Drum Setup parameter
values will be initialized. Selecting a Drum Set will
cause the Drum Setup parameter values to be
initialized.
2.1.5 MU10 Native Parameter Change
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
Device Number
01001001
49
Model ID
0aaaaaaa
aa
Address High
0aaaaaaa
aa
Address Mid
0aaaaaaa
aa
Address Low
0ddddddd
dd
Data
|
|
11110111
F7
End of Exclusive
2.1.5.1 MU10 System Data parameter change
See Tables 2-1 and 2-2.
2.1.6 Other parameter changes
2.1.6.1 Master Tuning
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
Device Number
00100111
27
Model ID
00110000
30
Sub ID2
00000000
00
00000000
00
0mmmmmmm
mm
Master Tune MSB
01111111
11
Master Tune LSB
Occccccc
cc
irrelevant
11110111
F7
End of Exclusive
This message simultaneously changes the pitch of
all channels.
2.2 Bulk Dump
The MU10 receives the following bulk dump data.
[ XG NATIVE ]
1) XG System Data
2) Multi Effect1 Data
3) Multi Part Data
4) A/D Part Data
5) Drums Setup Data
2.1.4.1 XG System On
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
Device Number
01001100
4C
XG Model ID
00000000
00
Address High
00000000
00
Address Mid
01111110
7E
Address Low
00000000
00
Data
11110111
F7
End of Exclusive
When this data is received, the MU10 will switch
to XG mode and all the parameters will be
initialized accordingly, and XG-compatible
messages such as NRPN and Bank Select messages
can be received. However, A/D part parameter
settings except Variation Send value will be
preserved (Variation Send will be initialized to the
value of 0).
Since approximately 50ms is required to execute
this message, be sure to leave an appropriate
interval before the subsequent message.
PERFORMANCE MODE CHANGE
(XG mode / TG300B mode)
XG System On = F0 43 1n 4c 00 00 7E 00 F7
TG300B Reset = F0 41 1n 42 12 40 00 7F 00
41 F7
n = device number
2.1.4.2 XG System Data parameter change
See Tables 1-1 and 1-2.
Summary of Contents for MU10
Page 1: ...3 ...
Page 64: ...2 M D G EMI Division Yamaha Corporation 1996 ...