MG206C-USB/MG206C
40
2-7
Frequency Characteristic
In the signal route
1
to
7
specified in the table 2-6-1 to 2-6-6, check the 20 Hz and 20 kHz frequency response of each output
is within the range of +1/-2.5 dB compared with the 1 kHz (0 dB).
*
When the GAIN control is set to maximum, only 20 Hz frequency response is within the range of +1/-4.5 dB compared with
the 1 kHz (0 dB).
*
In the signal route
1
, check every OUT when the signal is input to CH1, and check only the ST L OUT when the signal is
input to CH2 and other channels.
*
In the signal route
2
to
7
check only the ST L OUT and the ST R OUT.
2-8
HPF
With controls set as specified in the table 2-6-1, table 2-6-3 and 2-6-4, set the GAIN control minimum and input 80 Hz, -36 dBu
signal to the input terminal. Set the 80 switch on and then check the output level obtained at ST L OUT is within the range of
-3
±
2 dB compared with the output level obtained when 80 switch is off.
2-9
Channel Equalizer Characteristics
With controls set as specified in the section 2-2, move each equalizer gain control (HIGH, MID, LOW) respectively and check
the output level obtained at GROUP1 OUT and GROUP2 OUT for each frequency is within the range specified in the table 2-
9-1 and 2-9-2 compared with the output level obtained when each equalizer gain control is at center click position.
If the output level is out of range, change the input frequency within the range of
±
20 % and check the output level is within the
range specified in the table 2-9-1 and table 2-9-2.
Table 2-9-1 CH (1-12)
2-10 Crosstalk
Set ON switch and ST switch of each input channel to ON, and turn the PAN control (PAN/BAL or BAL control in case of ST CH
INPUT) counterclockwise fully, check the leakage signal level obtained at ST R OUT is -50 dBu or less when the output level
obtained at ST L OUT is +20 dBu.
Also turn the PAN (PAN/BAL, BAL) control clockwise fully, check the leakage signal level obtained at ST L OUT is -50 dBu or
less when the output level obtained at ST R OUT is +20 dBu.
2-11 PEAK indicator light-up level
With controls set as specified in the section 2-2, input signal to the CH INPUT MIC and ST INPUT MIC. Then check the input
level is within the range specified in table 2-11 when the PEAK indicator lights up.
Table 2-11
Equalizer gain control
Max.
Min.
Max.
Min.
Max.
Min.
Input frequency
10 kHz
2.5 kHz
100 Hz
Variation width
+12
±
2 dB
-12
±
2 dB
+15
±
2 dB
-15
±
2 dB
+12
±
2 dB
-12
±
2 dB
Equalizer control
HIGH
MID
LOW
INPUT
MIC (CH1-12)
ST CH MIC
(CH 13/14-19/20)
PEAK indicator
-43
±
3 dBu
-49
±
3 dBu
Table 2-9-2 CH (13/14-19/20)
Equalizer gain control
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Frequency control
-
-
Max.
Min.
-
-
Variation width
+12
±
2 dB
-12
±
2 dB
+15
±
2.5 dB
-15
±
2.5 dB
+15
±
2.5 dB
-15
±
2.5 dB
+12
±
2 dB
-12
±
2 dB
Equalizer control
HIGH
MID
LOW
Input frequency
10 kHz
5 kHz
250 Hz
100 Hz
Summary of Contents for MG206c-USB
Page 3: ...MG206C USB MG206C 3 SPECIFICATIONS Electrical Specifications General Specifications ...
Page 5: ...MG206C USB MG206C 5 総合仕様 電気的特性 一般仕様 ...
Page 6: ...MG206C USB MG206C 6 アナログ入力仕様 アナログ出力仕様 デジタル入出力仕様 MG206C USBのみ ...
Page 31: ...MG206C USB MG206C 31 B B Pattern side パターン側 2NA WJ26400 1 MG206C USB MG206C Reduction 4 5 ...
Page 35: ...MG206C USB MG206C 35 B B Reduction 3 5 2NA WJ26350 MG206C USB MG206C Pattern side パターン側 ...