3. How to cancel test mode
(Entry of EEPROM adjustment value)
1) Be sure to perform AUTO preliminary adjustment, AUTO adjustment and AUTO AFB adjustment.
( “
COMPLETE
” appears on the display)
2) After completing above ajustments, press the REC button. (Entry to EEPROM initiates then.)
The TEST mode is completed. ( “
Test
End
” appears on the display)
3) Press the EJECT button to take out the disc.
4) Turn off the power.
2. How to set to each mode
Every time the DISPLAY (forward) or EDIT (reverse) button is pressed, the mode changes. (For operation of each
mode, refer to the section describing each mode.)
Since this mode is not required for servic-
ing , proceed to another mode promptly.
*
AUTO_AJST
(AUTO adjustment)
@
AUT_AFB
(AUTO AFB adjustment)
@
RST_YOBI
(RESULT preparation)
@
RESULT
(RESULT)
@
MNU_YOBI
(MANUAL preliminary adjustment)
@
MNU_AJST
(MANUAL adjustment)
@
EEPROM_SET
(EEPROM setting)
@
AUT_YOBI
(AUTO preliminary adjustment)
@
Panel key
Function
Command code
REC
TEST mode end (entry of EEPROM)
1F
H
EJECT
Eject
B3
H
DISPLAY
Menu feeding in TEST mode (1) / (Feeding of menus mainly related to adjustment and EEPROM)
B2
H
TITLE
Menu feeding in TEST mode (2) / (Feeding of menus mainly related to continuous playback and continuous recording)
B4
H
CHARA.
Menu feeding in TEST mode (3) (Feeding of menus mainly related to INNER mode and JUMP SELECT)
F2
H
EDIT
Menu feeding in reverse in TEST mode (Menu feeding in reverse in each TEST mode)
A8
H
SET/ENTER
Finalization of menu selection or starting of its execution
A2
H
DELETE/CANCEL
Stopping each test item and shifting to menu selection at one step upper level
A7
H
SEARCH
w
Forced feeding of the slide (in FWD direction) / Execution of JUMP function (FWD)
AA
H
ADDRESS setting value increased / Specification of direction when setting the tracking
SEARCH
e
Forced feeding of the slide (in REV direction) / Execution of JUMP function (REV)
AC
H
ADDRESS setting value reduced / Specification of direction when setting the tracking
JOG DIAL
y
Forced feeding of the disc to EJECT / setting value increased
F3
H
JOG DIAL
t
Forced feeding of the disc to LOAD / setting value reduced
F4
H
INPUT
Switching of laser power at EJECT / switching of display for continuous playback / switching of digit setting when setting ADDRESS
F5
H
RANDOM
–
REPEAT S/F
–
REPEAT A-B
–
SCROLL
–
PLAY/PAUSE
–
STOP
–
●
Panel keys used in TEST mode