TRBL
SHTG
Troubleshooting
9-13
6D93G11
Bracket unit
9
Symptom: Power trim and tilt unit does not operate.
Listen for the operation sound
of the power trim and tilt relay.
Listen for the operation sound
of the power trim and tilt motor.
Check that the manual valve is
closed.
Disassemble and check the
power trim and tilt motor. (7-27)
Check the fuse for continuity.
Can the
specified battery
voltage be
obtained?
Can the
operation sound
be heard?
Can the
operation sound
be heard?
Replace the power
trim and tilt relay.
Check the voltage between the
sky blue (Sb) lead and light
green (Lg) lead.
Check the voltage between each terminal of the PTT relay
coupler when pushing the power trim and tilt switch.
• Between the sky blue (Sb) lead and black (B) lead.
• Between the light green (Lg) lead and black (B) lead.
Yes
No
Yes
No
Yes
No
No
Yes
Continued on next page.
Replace the power
trim and tilt relay.
Yes
No
Replace the fuse.
Is there
continuity?
Check for continuity between
the battery, relays, and power
trim and tilt switch.
Can the
specified battery
voltage be
obtained?
Summary of Contents for F80B
Page 1: ...F80B F100D SERVICE MANUAL 6D9 28197 3G 11 ...
Page 4: ......
Page 46: ...CHK ADJ Periodic checks and adjustments 3 17 6D93G11 MEMO ...
Page 148: ...LOWR Lower unit 6 25 6D93G11 Shimming 6 ...
Page 153: ...6D93G11 6 30 1 2 3 4 5 6 7 8 9 MEMO Backlash ...
Page 215: ...6D93G11 8 12 1 2 3 4 5 6 7 8 9 S60V8265 Br B Fuel control system Starting system ...
Page 245: ...6D93G11 i 5 1 2 3 4 5 6 7 8 9 Index MEMO ...
Page 247: ......
Page 248: ...YAMAHA MOTOR CO LTD Printed in the Netherlands Nov 2004 1 2 1 CR E ...