41
EMX5000-12/20
3
FREQUENCY RESPONSE
• In each state as described in Tables 2-1, 2-2, 2-3 and 2-4, input a signal at the frequency of 20Hz and 20kHz and check that
the output level at each output terminal is within the range of +1/-3dB with 1kHz used as a reference. At 20Hz with the GAIN
control set at the MAX position only, however, check that the output level is within the range of +1dB/-4.5dB. For PHONES,
take measurement at 2TR IN input terminal.
4
EQUALIZER CHARACTERISTICS
• In the state as described in 1, move each EQ control of INPUT and check that the output level of the frequency obtained at ST
OUT falls within the range given in Table 4-1 with the output level obtained at the center click position used as a reference.
If the output level at a specified frequency does not fall within the range given in Table 4-1, vary the frequency and check that
the output level as specified in the table below is obtained. Also, check that the frequency variation at this time is within the
range of specified frequency
±
20%.
*1: Turn on the PFL switch.
[Table 2-4] Input terminal [ST SUB IN (1, 2)]
[Unit: dBs]
INPUT
INPUT LEVEL
ST OUT L
ST OUT R
AUX 1, 2 SEND
PHONES L *1
PHONES R *1
L/MONO
-6
+10
±
2
+10
±
2
+13
±
2
-1
±
2
-1
±
2
R
-6
–
+10
±
2
+7
±
2
–
-1
±
2
*1: Turn on the PFL switch.
[Table 2-5] Input terminal [2TR IN]
[Unit: dBs]
INPUT
INPUT LEVEL
ST OUT L
ST OUT R
PHONES L *1
PHONES R *1
L
-17.8
+10
±
2
–
-1
±
2
–
R
-17.8
–
+10
±
2
–
-1
±
2
[Table 2-6 ] Input terminal [CH1: INPUT A], Output terminal [PHONES (L, R)]
[Unit: dBs]
INPUT LEVEL
GAIN
ST AFL ON
MONO AFL ON
AUX 1, 2 AFL ON
-46
MIN.
-4
±
2
-1
±
2
-5
±
2
[Table 4-1] (INPUT CH1-8: EMX5000-12 / 1-16: EMX5000-20)
[Unit: dBs]
EQ
level control
f control
Input frequency
Variation width
LOW
MAX.
–
10KHz
+12
±
2
MIN.
–
-12
±
2
MAX.
MIN.
250KHz
+15
±
2.5
MID
MIN.
-15
±
2.5
MAX.
MAX.
5KHz
+15
±
2.5
MIN.
-15
±
2.5
HIGH
MAX.
–
100Hz
+12
±
2
MIN.
–
-12
±
2
[Table 4-2] Input terminal [ST INPUT, CH9-12: EMX5000-12 / CH17-20: EMX5000-20] [Unit: dBs]
EQ
level control
Input frequency
Variation width
LOW
MAX.
100Hz
+12
±
2
MIN.
-12
±
2
MID
MAX.
2.5KHz
+15
±
2.5
MIN.
-15
±
2.5
HIGH
MAX.
10KHz
+12
±
2
MIN.
-12
±
2
4a HPF characteristic
• In the state as described in 1, set the input signal level to 80Hz and turn on the HPF switch of CH INPUT 1 and check that the
output level of ST OUT L is within the range of –3
±
2dB with the level at the HPF switch OFF used as a reference.
Summary of Contents for EMX 5000-12
Page 5: ...EMX5000 12 20 5 ...
Page 6: ...EMX5000 12 20 6 ...
Page 27: ...EMX5000 12 20 27 IN8 IN16 3NA V826740 A A ...
Page 28: ...EMX5000 12 20 28 A A B B IN8 IN16 3NA V826740 ...
Page 29: ...EMX5000 12 20 29 Pattern side B B IN8 IN16 3NA V826740 ...
Page 33: ...EMX5000 12 20 33 MAS 3NA V826750 A A ...
Page 34: ...EMX5000 12 20 34 MAS 3NA V826750 A A B B ...
Page 35: ...EMX5000 12 20 35 Pattern side MAS 3NA V826750 B B ...
Page 46: ...EMX5000 12 20 46 ...
Page 47: ...47 EMX5000 12 20 ...
Page 48: ...EMX5000 12 20 48 ...
Page 49: ...49 EMX5000 12 20 ...
Page 50: ...EMX5000 12 20 50 ...
Page 51: ...51 EMX5000 12 20 ...
Page 52: ...EMX5000 12 20 52 ...
Page 53: ...53 EMX5000 12 20 ...