7-2
Trouble recovery
Output indicator(s) do not come on
Overload indicator light does not turn off
The device(s) that had been working correctly before do not work
Multi-function LED meter flash or come on abnormally
Item
Check
Action
Page
Overload indicator
light
Does the overload indicator
light come on?
Make sure that the total watt-
age of connected device(s) is
within the rated range.
Is the overload indicator light
flashing?
Some malfunctions have been
detected. Consult a Yamaha
dealer.
—
The reset button does not
function even while the over-
load indicator light is coming
on.
Consult a Yamaha dealer.
—
Item
Check
Action
Page
Receptacle(s)
Are the device(s) plugged out
from the receptacle(s)?
Plug out any connected devic-
es from the receptacle(s).
—
Item
Check
Action
Page
Device(s)
Are you using an extension
cord?
Connect the device(s) directly
without using extension cords.
—
Do the device(s) stop due to a
voltage drop?
It is not recommended to use
devices that are sensitive to
voltage fluctuation. Also make
sure that the total wattage of
connected device(s) is within
the rated range.
Display
Check
Action
Page
Are some of the output in-
dicator(s) and overload in-
dicator light off even when
the engine is started?
Consult a Yamaha dealer.
—
Do the output indicator(s)
and the overload indicator
light come on for a few
seconds immediately after
starting the engine?
It is not a malfunction. The
multi-function LED meter is in
self-diagnostic mode.
—
7PC-F8199-U0-E0.book 2 ページ 2019年5月21日 火曜日 午後3時11分
Summary of Contents for EF2200iS
Page 2: ...7PC F8199 U0_cover indd 2 2019 05 21 15 14 55 ...
Page 16: ...1 9 Safety information 6 7 8 9 7PC F8199 U0 E0 book 9 ページ 2019年5月21日 火曜日 午後3時11分 ...
Page 63: ...7PC F8199 U0 E0 book 2 ページ 2019年5月21日 火曜日 午後3時11分 ...
Page 69: ...7PC F8199 U0 E0 book 2 ページ 2019年5月21日 火曜日 午後3時11分 ...
Page 70: ...Printed in China 2019 05 1 E 7PC F8199 U0 E0 book 1 ページ 2019年5月21日 火曜日 午後3時11分 ...
Page 71: ...7PC F8199 U0_cover indd 2 2019 05 21 15 14 55 ...