3-26
CRANKSHAFT, PISTON AND PISTON RING
1
1
2
CONNECTING ROD OIL
CLEARANCE
INSPECTION
NOTE:
Measure the oil clearance if replacing the
crankshaft or connecting rod.
1. Place a piece of Plastigauge
1
on the
crank pin horizontally.
NOTE:
Clean off oil from all parts thoroughly.
2. Install:
9
Connecting rod
1
9
Connecting rod cap
1
NOTE:
Tighten the cap bolts so that the crankshaft
does not move while the oil clearance is being
measured.
3. Remove:
9
Connecting rod cap
9
Connecting rod
4. Measure:
9
Connecting rod oil clearance
Widest portion of the pressed
Plastigauge
Out of specification
→
Replace crank-
shaft or connecting rod, and then mea-
sure the clearance again.
ENG
Connecting rod oil clearance:
0.015 ~ 0.050 mm
(0.0006 ~ 0.0020 in)
Limit:
0.100 mm
(0.004 in)
6 Nm (0.6 m · kg, 4.3 ft · lb)