5-8
GENERATOR SYSTEM
ELEC
GENERATOR SYSTEM
TROUBLESHOOTING CHART
WEAK OR NO AC CURRENT
Start the engine.
Check the overload warning light.
DOES NOT TURN ON
TURNS ON
Start the engine.
Check the pilot light.
DOES NOT TURN ON
TURNS ON
Rated engine speed inspection.
9
Operate the engine with no load.
9
Set the economy switch to “OFF”.
5,000 r/min
GOOD
OUT OF SPECIFICATION
Check the overload warning light.
TURNS ON
DOES NOT TURN ON
Check the pilot light.
Check the throttle control system.
Refer to “THROTTLE CONTROL SYSTEM” in
CHAPTER 6.
AC coil 1 AC voltage inspection
9
Connect Brown-Green (R-S), Green-Brown (S-T),
and Brown-Brown (R-T) leads.
9
Start the engine, then measure the voltage. (Tester
range: AC300V)
GOOD
TOO LOW
DOES NOT GENERATE
AC coil 1
W
Or
W
W
W
W
Br
G
Br
Br
Br
Br
R
S
T
R
S
T
AC coil 2
AC coil 1 AC voltage:
130 ~ 260 V at 20 °C (68 °F)
Magnetic force is weak.
Replace the magneto rotor.
AC coil 1 resistance inspection
9
Stop the engine.
9
Measure the resistance between Brown-Green
(R-S), Green-Brown (S-T), and Brown-Brown (R-T)
leads. (Tester range:
Ω ×
1)
SPECIFICATION
OUT OF SPECIFICATION
W
Or
W
Br
G
Br
AC coil 1
R
S
T
R
S
T
AC coil 2
AC coil 1 resistance:
0.47
Ω
± 20% at 20 °C (68 °F)
Replace the AC coil 1.
*
7VV10-05 02.10.7 1:55 PM Page 8
Summary of Contents for EF1000iS
Page 1: ...SERVICE MANUAL EF1000iS LIT 19616 01 02 7VV 28197 10 310137 ...
Page 13: ...GEN INFO ...
Page 30: ...INSP ADJ ______ l t t l ...
Page 66: ...ENG Iiii ...
Page 75: ...CARB1 _ I ...
Page 93: ...TRBLI I ...
Page 109: ...PRINTED ON RECYCLED PAPER PRINTED IN USA YAMAHA MOTOR CO LTD E ...