Check the armature for continuity.
Replace if out of specifications.
Checking the brushes
1.
Measure the brush length
a
. Replace
the brush assembly if below specifica-
tion.
2.
Check the brush holder assembly for
continuity. Replace if out of specifica-
tions.
Checking the starter motor operation
1.
Check the operation of the starter motor
after installing it onto the power unit.
a
6F680200
Brush length limit
a
:
9.0 mm (0.35 in)
6F680190
c
d
e
69D80160
1
2
Armature continuity
Commutator segments
c
Continuity
Segment – Armature core
d
No continuity
Segment – Armature shaft
e
No continuity
Brush continuity:
Brush holder
1
—
No continuity
Brush base
2
69D5G11_08 04.9.24 9:22 Page 20