General Specifications
Sampling frequency
Power requirements
Power length and temperature range
Specifications
Conditions
Min.
Typ.
Max.
Unit
External clock
Frequency range
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
–1000
—
+1000
ppm
Jitter of PLL
*1
*1.
Input clock jitter must be 1 ns or less.
WORD CLOCK IN Fs= 44.1 kHz, 48 kHz, 88.2 kHz,
96 kHz
—
—
10
ns
Internal clock
Frequency
Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz
—
44.1
48
88.2
96
—
kHz
Accuracy
Word clock : int 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
–50
—
+50
ppm
Jitter
*2
*2.
Measured at the WORD CLOCK OUT connector.
Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz
—
—
4.5
4.1
2.3
2.1
ns
Conditions
Min.
Typ.
Max.
Unit
Power consumption
100–240 V 50/60 Hz
—
—
190
W
Heating value
100–240 V 50/60 Hz
—
—
164
kcal/h
Conditions
Min.
Typ.
Max.
Unit
Power cord length
—
250
—
cm
Temperature range
Operating temperature range
0
—
40
°C
Storage temperature range
–20
—
60
°C