background image

Explanation of Graphical Symbols
Explication des symboles

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated 
“dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

L’éclair avec une flèche à l’intérieur d’un triangle équilatéral est destiné à attirer l’attention de l’utilisateur sur la présence d’une 
« tension dangereuse » non isolée à l’intérieur de l’appareil, pouvant être suffisamment élevée pour constituer un risque d’électrocution.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the product.

Le point d’exclamation à l’intérieur d’un triangle équilatéral est destiné à attirer l’attention de l’utilisateur sur la présence d’instructions 
importantes sur l’emploi ou la maintenance (réparation) de l’appareil dans la documentation fournie.

IMPORTANT SAFETY 
INSTRUCTIONS

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in accordance with 
the manufacturer’s instructions.

8

Do not install near any heat sources such as radiators, heat 
registers, stoves, or other apparatus (including amplifiers) that 
produce heat.

9

Do not defeat the safety purpose of the polarized or grounding-
type plug. A polarized plug has two blades with one wider than the 
other. A grounding type plug has two blades and a third grounding 
prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

10 Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the point where 
they exit from the apparatus.

11 Only use attachments/accessories specified by the manufacturer.
12 Use only with the cart, stand, tripod, bracket, or 

table specified by the manufacturer, or sold with 
the apparatus. When a cart is used, use caution 
when moving the cart/apparatus combination to 
avoid injury from tip-over.

13 Unplug this apparatus during lightning storms or 

when unused for long periods of time.

14 Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way, such 
as power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has 
been dropped.

(UL60065_03)

PRÉCAUTIONS CONCER-
NANT LA SÉCURITÉ

1

Lire ces instructions.

2

Conserver ces instructions.

3

Tenir compte de tous les avertissements.

4

Suivre toutes les instructions.

5

Ne pas utiliser ce produit à proximité d’eau.

6

Nettoyer uniquement avec un chiffon propre et sec.

7

Ne pas bloquer les orifices de ventilation. Installer l’appareil 
conformément aux instructions du fabricant.

8

Ne pas installer l’appareil à proximité d’une source de chaleur 
comme un radiateur, une bouche de chaleur, un poêle ou tout autre 
appareil (y compris un amplificateur) produisant de la chaleur.

9

Ne pas modifier le système de sécurité de la fiche polarisée ou de 
la fiche de terre. Une fiche polarisée dispose de deux broches dont 
une est plus large que l’autre. Une fiche de terre dispose de deux 
broches et d’une troisième pour le raccordement à la terre. Cette 
broche plus large ou cette troisième broche est destinée à assurer 
la sécurité de l’utilisateur. Si la fiche équipant l’appareil n’est pas 
compatible avec les prises de courant disponibles, faire remplacer 
les prises par un électricien.

10 Acheminer les cordons d’alimentation de sorte qu’ils ne soient pas 

piétinés ni coincés, en faisant tout spécialement attention aux 
fiches, prises de courant et au point de sortie de l’appareil.

11 Utiliser exclusivement les fixations et accessoires spécifiés par le 

fabricant.

12 Utiliser exclusivement le chariot, le stand, le 

trépied, le support ou la table recommandés par 
le fabricant ou vendus avec cet appareil. Si 
l’appareil est posé sur un chariot, déplacer le 
chariot avec précaution pour éviter tout risque 
de chute et de blessure.

13 Débrancher l’appareil en cas d’orage ou lorsqu’il 

doit rester hors service pendant une période prolongée.

14 Confier toute réparation à un personnel qualifié. Faire réparer 

l’appareil s’il a subi tout dommage, par exemple si la fiche ou le 
cordon d’alimentation est endommagé, si du liquide a coulé ou des 
objets sont tombés à l’intérieur de l’appareil, si l’appareil a été 
exposé à la pluie ou à de l’humidité, si l’appareil ne fonctionne pas 
normalement ou est tombé.

(UL60065_03)

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, 

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

ATTENTION : 

POUR RÉDUIRE LES RISQUES D'ÉLECTROCUTION, NE PAS RETIRER 

LE CAPOT (OU LE DOS). NE CONTIENT PAS DE PIÈCES NÉCESSITANT 

L'INTERVENTION DE L'UTILISATEUR. POUR TOUTE INTERVENTION, 

FAIRE APPEL À DES PROFESSIONNELS QUALIFIÉS.

ATTENTION

RISQUE DE CHOC 

ELECTRIQUE-NE PAS OUVRIR

The above warning is located on the top/rear of the unit.

L’avertissement ci-dessus est situé sur le dessus/l’arrière de l’unité.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

AVERTISSEMENT

POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE 

ÉLECTRIQUE, N’EXPOSEZ PAS CET APPAREIL À LA PLUIE OU À 

L’HUMIDITÉ.

DSP-RX(-EX) Owner’s Manual

2

Summary of Contents for DSP-RX

Page 1: ...SIGNAL PROCESSOR DSP ENGINE DSP RX EX DSP RX Owner s Manual EN ...

Page 2: ...ropped UL60065_03 PRÉCAUTIONS CONCER NANT LA SÉCURITÉ 1 Lire ces instructions 2 Conserver ces instructions 3 Tenir compte de tous les avertissements 4 Suivre toutes les instructions 5 Ne pas utiliser ce produit à proximité d eau 6 Nettoyer uniquement avec un chiffon propre et sec 7 Ne pas bloquer les orifices de ventilation Installer l appareil conformément aux instructions du fabricant 8 Ne pas i...

Page 3: ...te either this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lead in is 300 ohm ribbon lead change the lead in to co axial type cable If these corrective measures do not produce satisf...

Page 4: ...t Use only the supplied power cord plug If you intend to use the product in an area other than in the one you purchased the included power cord may not be compatible Please check with your Yamaha dealer Check the electric plug periodically and remove any dirt or dust which may have accumulated on it Make sure to fully insert the electric plug to prevent electric shocks or fire This product receive...

Page 5: ...damage to the product s When the backup battery needs to be replaced Low Battery or No Battery will appear on the display In this case contact your Yamaha dealer and have qualified Yamaha service personnel replace the backup battery NOTICE To avoid the possibility of malfunction damage to the product damage to data or damage to other property follow the notices below Handling and maintenance Do no...

Page 6: ... You should note this serial number in the space provided below and retain this manual as a permanent record of your purchase to aid identification in the event of theft Model No Serial No Information for users on collection and disposal of old equipment This symbol on the products packaging and or accompanying documents means that used electrical and electronic products should not be mixed with g...

Page 7: ...2 Installing and Removing Optional Cards 13 Installing a Mini YGDAI Card 13 Removing the Mini YGDAI Card 13 Installing an HY Card 14 Removing the HY Card 15 Power Supply 15 Connecting the AC Power Cord 15 Turning the Power On and Off 15 About DEK DSP RX 16 Troubleshooting 16 Restoring the Factory Programmed Settings 16 On screen Messages 17 Specifications 19 General Specifications 19 Pin Assignmen...

Page 8: ...s for Rack Mounting This unit is rated for operation at ambient temperatures ranging from 0 to 40 degrees Celsius If you mount this unit along with other DSP unit s or other device s in an EIA standard equipment rack temperatures inside the rack may rise possibly resulting in impaired performance When rack mounting the unit always observe the following requirements to avoid heat buildup When mount...

Page 9: ... is attached on the DSP RX EX The DSP RX does not feature this badge Green Normal Yellow lit steadily Indicates a minor issue but you can continue using the unit Red flashing A critical error has occurred Unit ID Specifies the Unit ID for the unit You must set a unique ID for each device connected to the same I O network so that they will be identified correctly For more information on setting the...

Page 10: ...disconnect the power cord remove it while pressing the latch on the plug 3 MIDI OUT IN jacks These jacks are used to transmit receive MIDI messages to from external MIDI devices 4 REMOTE connector This D sub 9 pin male connector transmits and receives signals to enable you to control the unit from external devices This feature will be supported by a future update 5 Serial communication switch Enab...

Page 11: ...status TX RX indicators The appropriate indicator flashes green when data is transmitted from TX or received at RX the CONSOLE NETWORK OUT IN connectors NETWORK connector This RJ 45 connector allows the unit to be connected to a computer via an Ethernet cable CAT5 or higher recommended This is used mainly for controlling mix parameters or editing scene memory and libraries from the dedicated RIVAG...

Page 12: ... panel on the unit Preparation Cable preparation Use strand wires for the Euroblock plug First strip the strand wire insulation as shown below After the strand wires are connected to the Euroblock plug the wires may break due to metal fatigue caused by the weight of the cable or vibration For a rack mount use wire binding bar if possible to bind the wires together and secure them If you plan to co...

Page 13: ... place for future use 3 Align both edges of the card with the guide rails inside the slot and then insert the card into the slot Push the card all the way into the slot so that the connector at the end of the card is correctly inserted into the connector inside the slot 4 Fasten the card using the screws attached to the card If the card is not fastened securely component failure or malfunction may...

Page 14: ...allation lever pressed down NOTE For information on which cards support each slot refer to Part Names and Functions on page 11 Push the card all the way into the slot so that the connector at the end of the card is correctly inserted into the connector inside the slot 4 Pull up the card installation lever to lock in the card Make sure that the lever claw is securely locked under the bottom part of...

Page 15: ...he procedure described above To disconnect the power cord remove it while pressing the latch on the plug Warning Use only the supplied AC power cords Using other cables may lead to overheating or electric shock Caution Be sure to turn off the power to the unit before connecting or disconnecting the power cord NOTICE Even when the power switches are turned off a small amount of current is flowing t...

Page 16: ...hat it is installed properly Make sure that the cables are connected properly Restoring the Factory Programmed Settings Follow the steps below to initialize the internal memory of the unit excluding the Unit ID to the factory programmed settings NOTE For more information on setting the Unit ID refer to Setting the Unit ID in the RIVAGE PM series Operation Manual 1 While the unit s power is on pres...

Page 17: ...nserted in the MY card slot is not accessible A number sign indicates the slot number in relation with the corresponding error ERR H0 H W ERROR HY SLOT Red flashing A card inserted in the HY card slot is not accessible A number sign indicates the slot number in relation with the corresponding error ERR T11 TWINLANe T V B OP IP Red flashing The optical transceiver module on the HY256 TL is faulty T...

Page 18: ...looped back to the unit itself IN OUT 5 Input connectors are connected to each other IN IN 6 Output connectors are connected to each other OUT OUT Check the cable connection ERR T08 CONSOLE NETWK OPEN LOOP Yellow lit steadily Ethernet cable is not connected properly The Console network loop is not closed Check the cable connection ERR W01 BNC UNLOCK Red flashing The unit is unable to lock to the w...

Page 19: ... clock int 44 1 kHz Word clock int 48 kHz Word clock int 88 2 kHz Word clock int 96 kHz 44 1 48 88 2 96 kHz Accuracy Word clock int 44 1 kHz 48 kHz 88 2 kHz 96 kHz 50 50 ppm Jitter 2 2 Measured at the WORD CLOCK OUT connector Word clock int 44 1 kHz Word clock int 48 kHz Word clock int 88 2 kHz Word clock int 96 kHz 4 5 4 1 2 3 2 1 ns Conditions Min Typ Max Unit Power consumption 100 240 V 50 60 H...

Page 20: ...TTL logic input voltage 0 5 V CH 8 Optocoupler input voltage 0 24 V Low level 1 V High level 5 V Outputs CH 1 7 Open drain Max external supply voltage 12 V Max sink current per pin 75 mA CH 8 Relay Contact Max 1 A 30 V DC Power Supply Pins 5 V 5 Max total output current 600 mA REMOTE RS422 232C 3 3 Toggled by the switch D sub 9 pin male FAULT OUTPUT NO DC 30 V 1 A Euroblock Connector 3P C 4 4 The ...

Page 21: ...then download the manual file Pin No Signal 1 NO Normally Open 2 C Common 3 NC Normally Closed 1 2 3 Pin No Signal Pin No Signal 1 GPO1 14 GPO2 2 GPO3 15 GPO4 3 GPO5 16 GPO6 4 GPO7 17 RLY_NC 5 RLY_C 18 RLY_NO 6 GND 19 GND 7 GND 20 OPTO 8 OPTO 21 5V 9 5V 22 GPI1 10 GPI2 23 GPI3 11 GPI4 24 GPI5 12 GPI6 25 GPI7 13 N C 14 15 16 13 1 2 3 25 M2 6 x 0 45 mm pitch 444 450 491 15 480 220 Approximate Munsel...

Page 22: ...t Output 9 Firmware Updates 8 H HY Card Installing 14 Removing 15 I Initialization 16 Initialz Initialize 9 M Mini YGDAI card Installing 13 Removing 13 Mirr Chk Mirror Check 9 O On screen Messages 17 Optional Cards 13 R Rack Mounting 8 Recessed Installation 8 S Settings Brightns Brightness 9 Contrast 9 F W Ver Firmware Version 9 Fan Spd Fan Speed 9 FaultOut Fault Output 9 Initialz Initialize 9 Mir...

Page 23: ...6686168 SWEDEN FINLAND ICELAND Yamaha Music Europe GmbH Germany filial Scandinavia JA Wettergrensgata 1 400 43 Göteborg Sweden Tel 46 31 89 34 00 DENMARK Yamaha Music Denmark Fillial of Yamaha Music Europe GmbH Tyskland Generatorvej 8C ST TH 2860 Søborg Denmark Tel 45 44 92 49 00 NORWAY Yamaha Music Europe GmbH Germany Norwegian Branch Grini Næringspark 1 1332 Østerås Norway Tel 47 6716 7800 CYPRU...

Page 24: ...Yamaha Downloads https download yamaha com Yamaha Pro Audio global website http www yamahaproaudio com Manual Development Group 2020 Yamaha Corporation Published 05 2020 IPES B0 VEE1300 ...

Reviews: